P/N 3100897-EN • REV 05 • ISS 10DEC14 1 / 2
FW-SP4I Serial Port Expander
Card Installation Sheet
Description
The FW-SP4I Serial Port Expander Card adds four optically isolated
serial ports to a FireWorks workstation.
Note: FireWorks 1.41 or later is required.
Package contents
The following items are included with the FW-SP4I:
Four RJ-45 to DB-9 adapter cables
One bag of jumpers
One Connect Tech BlueStorm/Express driver CD
Configuration
The FW-SP4I card does not require configuration. It is shipped already
configured for RS-232 operation (no jumpers installed).
Installation
Caution: Equipment damage hazard. This product is sensitive to
electrostatic discharge (ESD). To avoid damage, follow accepted ESD
handling procedures.
Installing the FW-SP4I card:
1. Turn off the workstation, and then disconnect AC power.
2. Remove the cover. See Figure 1.
3. Remove the expansion card hold-down bracket. See Figure 2.
4. Choose an available PCI expansion slot, and then remove the
expansion slot cover.
5. Remove the FW-SP4I card from the antistatic bag. Note the serial
number in the upper left corner of the card.
Note: Hold the card by its edges. Do not touch any components,
connector pins, or circuits.
6. Insert the FW-SP4I card into the PCI expansion slot. Push down
on the card until it is fully seated.
7. Secure the card to the workstation chassis, and then replace the
expansion card hold-down bracket.
8. Close the workstation.
Figure 1: Removing the cover
Figure 2: Removing the expansion card hold-down bracket
Installing the device driver:
1. Turn on the workstation, and then log on to the Administrator user
account.
2. Insert the Connect Tech BlueStorm/Express driver CD.
Close the Found New Hardware dialog box, if it appears.
3. Open Windows Device Manager.
4. Double-click Other Devices. The FW-SP4I appears as two PCI
serial port devices. The first device is serial ports 1 and 2. The
second device is serial ports 3 and 4.
5. Under Other Devices, right-click the first PCI Serial Port device,
and then click Update Driver Software.
6. Click Browse My Computer for Driver Software.
7. Under Search for Driver Software in This Location, click Browse,
select the D:\ Drivers\WIN_2K_XP_VISTA_7 folder, and then click
OK.
8. Click Install.
9. Repeat steps 5 through 8 for the remaining (second) PCI Serial
Port device.
10. Restart the workstation.
Question and Answer IconNeed help?

Do you have a question about the Edwards FW-SP4I and is the answer not in the manual?

Overview

The FW-SP4I Serial Port Expander Card is a device designed to add four optically isolated serial ports to a FireWorks workstation. It is compatible with FireWorks 1.41 or later.

Function Description

The primary function of the FW-SP4I card is to expand the serial communication capabilities of a FireWorks workstation by providing four additional RS-232 COM ports. These ports are optically isolated, enhancing system reliability and protecting against electrical surges. The card is shipped pre-configured for RS-232 operation, requiring no additional jumper settings for standard use.

Important Technical Specifications

  • Mounting Space: Requires one PCI expansion slot.
  • RS-232 COM Ports: Four.
  • Optical Isolation: Each port is individually isolated up to 3 kVAC peak to peak, providing robust protection against electrical interference and ground loops.
  • Operating Environment:
    • Temperature: 32 to 120°F (0 to 49°C).
    • Relative Humidity: 0 to 93% noncondensing.
  • Included Components:
    • FW-SP4I card.
    • Four RJ-45 to DB-9 adapter cables.
    • One bag of jumpers (for advanced configuration, though not required for standard RS-232).
    • One Connect Tech BlueStorm/Express driver CD.

Usage Features

Installation

  1. Preparation: Turn off the workstation and disconnect AC power.
  2. Access: Remove the workstation cover and the expansion card hold-down bracket.
  3. Slot Selection: Choose an available PCI expansion slot and remove its cover.
  4. Card Handling: Remove the FW-SP4I card from its antistatic bag. Note the serial number on the upper left corner. Handle the card by its edges, avoiding contact with components, connector pins, or circuits to prevent electrostatic discharge (ESD) damage.
  5. Insertion: Insert the FW-SP4I card into the PCI expansion slot, pushing down until it is fully seated.
  6. Securing: Secure the card to the workstation chassis and replace the expansion card hold-down bracket.
  7. Closure: Close the workstation.

Device Driver Installation

  1. Login: Turn on the workstation and log on to the Administrator user account.
  2. Driver CD: Insert the Connect Tech BlueStorm/Express driver CD.
  3. Dialog Box: Close the "Found New Hardware" dialog box if it appears.
  4. Device Manager: Open Windows Device Manager.
  5. Identify Device: Under "Other Devices," the FW-SP4I will appear as two PCI serial port devices. The first device corresponds to serial ports 1 and 2, and the second device to serial ports 3 and 4.
  6. Update Driver (First Device): Right-click the first PCI Serial Port device, then click "Update Driver Software."
  7. Browse for Driver: Click "Browse My Computer for Driver Software."
  8. Select Driver Path: Under "Search for Driver Software in This Location," click "Browse," select the D:\ Drivers\WIN_2K_XP_VISTA_7 folder (assuming D: is the CD drive), and click "OK."
  9. Install: Click "Install."
  10. Repeat for Second Device: Repeat steps 5 through 8 for the remaining (second) PCI Serial Port device.
  11. Restart: Restart the workstation.

COM Port Assignments

Windows automatically assigns COM ports to the FW-SP4I card's serial ports. To view these assignments:

  1. Open Windows Device Manager.
  2. Double-click "Ports (COM & LPT)."
  3. Look for devices labeled "CTI PCI Express UART Serial Port 1" through "4." The Windows COM port numbers will be displayed in brackets, along with the FW-SP4I card's serial number (e.g., SN#0000xxxx).

Cable Connections

Connect the supplied RJ-45 to DB-9 adapter cables to the FW-SP4I card. These cables are designed for communication security level 0. It is important to limit connections to the same room, within 20 ft. (6.1 m), and enclose them in conduit or provide equivalent protection against mechanical injury.

Maintenance Features

  • No Configuration Required: The FW-SP4I card is shipped pre-configured for RS-232 operation, eliminating the need for initial jumper adjustments.
  • Driver Updates: The provided driver CD ensures compatibility with various Windows operating systems (Windows 2000, XP, Vista, 7). Regular driver updates from the manufacturer's website (www.edwardsutcfs.com) may be available for continued optimal performance and compatibility.
  • ESD Protection: Adherence to accepted ESD handling procedures during installation is crucial to prevent damage to the sensitive electronic components of the card.

Edwards FW-SP4I Specifications

General IconGeneral
BrandEdwards
ModelFW-SP4I
CategoryExtender
LanguageEnglish