Do you have a question about the EEVBlog 121GW and is the answer not in the manual?
Details regulatory compliance with FCC and IC standards.
Guidance on RF interference and operational warnings.
Highlights the main capabilities and specifications of the multimeter.
Details on data logging to SD card and Bluetooth LE.
Information on physical design and software support.
Specifies battery types and expected operational life.
Covers general operating conditions, display, and environmental specs.
Details protection limits for various measurement inputs.
Provides detailed specs for DC, AC, and mV voltage measurements.
Details specs for DC, AC, mA, and µA current measurements.
Specifications for measuring resistance and capacitance.
Specifications for diode testing and frequency measurements.
Specs for VA power, temperature, and continuity tests.
Describes the meaning of various compliance marks.
Details compliance with relevant international and US standards.
Explains warning and caution symbols used in the manual.
Lists essential warnings for safe operation and potential hazards.
Identifies and describes parts on the front of the multimeter.
Highlights features located on the back of the multimeter.
Explains the primary and secondary displays and bar graph.
Describes how to use the rotary switch to select modes.
Explains the operation of Low Z and Temperature measurement modes.
Details modes for frequency, continuity, resistance, and capacitance.
Covers various current (A, mA, µA) and power (VA) measurement modes.
Step-by-step guides for various voltage measurements.
Step-by-step guides for various current measurements.
Explains burden voltage and the meter's low burden capability.
Instructions for measuring VA power, including connection setup.
Guide on using the meter with a thermocouple for temperature readings.
Procedures for measuring resistance and continuity.
How to measure frequency and period.
Covers range change, holds, REL, MIN/MAX/AVG, backlight, data logging, bluetooth, setup.
Steps for addressing common issues and alerts.
Advice on keeping the meter clean and storing it properly.
| Resistance | 0.1Ω to 50MΩ |
|---|---|
| Continuity Test | Yes |
| Diode Test | Yes |
| True RMS | Yes |
| Safety Rating | CAT III 1000V, CAT IV 600V |
| DC Voltage | 0.1mV to 1000V |
| Frequency | 0.001Hz to 10MHz |
| Temperature | -200°C to 1372°C |
| Wireless Connectivity | Wi-Fi |
| DC Current | 0.1μA to 10A |
| AC Current | 0.1μA to 10A |
| Capacitance | 1nF to 100mF |
| Battery Type | Li-ion rechargeable |