EasyManua.ls Logo

effeff 495-107 - Master Code Configuration; User Code Management; Daily Lock Usage

effeff 495-107
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Changing the master code
LLActuate the system by pressing button “
E” on the key pad. The green
LED will flash twice.
LLEnter the old master code.
LLPress button “
P” to actuate programming mode.
LLEnter the new master code with a minimum of 2 and maximum
number of 6 digits.
LLConfirm entry by pressing the button “
P”. This switches off the
programming mode.
Example:
E 1234 P 4321 P
= new mastercode E 4321
Entering the mastercode also opens the door and allows access to the
programming mode.
Programming of user codes
The system can accept 3 additional codes besides the master. Each
user code is programmed into the system in one of these programming
slots 1P, 2P or 3P.
The first digit of a user code must never be identical with the first digit
of the master code ! Failure to observe this means that a complete
reset of all codes is necessary see “Error reset”. All programming has
to be done again.
LLActuate the system by pressing button “E” on the key pad. The green
LED will flash twice.
LLEnter the master code.
LLPress button “
P” to actuate programming mode.
LLTo enter the programming slot press either 1P ...
2P ...
3P ...
LLEnter the desired code with a maximum of 6 digits.
LLPress button “
P” and the code is accepted and programming mode is
switched off.
Programming of all the codes is done in the same manor.
Examples:
E 4321 P 1 P 78493 P
= 1st usercode E 78493
E 4321 P 2 P 539 P
=2nd usercode E 539
E 4321 P 3 P 7431 P
=3rd usercode E 7431
Operation of the code lock
(maximum entry time 13 secs.)
LLSwitching-on of operational standby mode by actuating the key “
E
on the membrane keypad.
The green LED indicator will flash on briefly twice, indicating entry
standby.
LLEntering one of the valid code numbers.
LLThe door handle is engaged for actuation for 3 seconds (in order to
open the door). During the door unlocking period the door handle can
be actuated only once.
If the door unlocking period of 3 seconds has expired without the door
having been opened, the door handle disengages (freerun).