21
Switching the pump on/o󰓐
1. Inside the aquarium: Attach the device below water level at the bottom or the inside
of your aquarium (⌦F). Pay attention to the maximum pond depth (see Technical
data).
Outside the aquarium: Attach the device to a stable surface outside of your
aquarium (⌦G).
2. Insert the mains plug in the mains socket. Attention: The pump starts immedi-
ately!
3. To turn it o󰘯, remove the mains plug from the mains socket.
Controlling the 󰄉ow rate
1. Turn the power controller to adjust the water 󰘱ow rate (⌦H).
6. Maintenance
DANGER! Electrocution!
All devices must be disconnected from the power supply before any maintenance
work is carried out.
CAUTION! Material damage.
Do not use hard objects or aggressive cleaning agents for cleaning.
The appliance components are not dishwasher-proof. Do not clean the appliance or
appliance parts in the dishwasher.
The following sections describe maintenance work necessary for optimum and fault-free
operation. Regular maintenance prolongs the service life and assures functionality of the
appliance over a long period.
Cleaning the pump
1. Remove the pump from the aquarium.
2. Loosen and remove the two lateral fastening screws
a
(⌦C).
3. Pull the pump cover
b
out of the engine body from the front.
4. Pull the impeller
e
out of the engine body (⌦I).
5. Clean all components under running water.
6. Install the pump again in reverse order.