EasyManua.ls Logo

Ei Electronics Ei2110 - Page 11

Ei Electronics Ei2110
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Additional Protection LD2: As LD3, but in addition
alarms in all rooms or areas that present a high fire
risk to occupants.
Heat Alarms located in:
(Heat Alarms must be within 5.3m of potential fire
sources)
each Kitchen
Multi-Sensor Fire Alarms or Heat Alarms located in:
each Living room (i.e. most frequently used
daytime room)
Multi-Sensor Fire Alarms located:
on each storey
every 7.5 m of hallways and escape routes
within 3m of all bedroom doors
(apart from toilets & bathrooms )
for new or materially altered dwellings or existing dwellings
with poor structural fire precautions
ADDITIONAL PROTECTION
LD2
Multi Storey Dwelling LD2
Living
Room
Bedroom Bathroom
Kitchen
Bedroom
Shower
Garage
Bedroom
Bedroom Bedroom
Kitchen / Dining Room
Living Room
Bathroom
Single Storey Dwelling LD2
Heat Alarm
do not fit alarm
Multi-Sensor Fire Alarm
B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 3:46 PM Page 11

Other manuals for Ei Electronics Ei2110

Related product manuals