9. Troubleshooting
Fault Cause Remedy
Engine does not start Automatic oil cut-out has not
responded
Spark plug fouled
No fuel
Check oil level, top up engine oil
Clean or replace spark plug
(electrode spacing 0.6 mm)
Refuel / have the petrol cock
checked
Generator has too little or no
voltage
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air filter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the filter