Read these instructions carefully and
keep them in a safe place.
Layout (Fig. 1)
1 ON/OFF switch with air humidity adjuster
2 “W.F.” LED for condensate collector full
3 ”Power” LED
4 Air outlet grille
5 Handle
6 Front housing panel
7 Condensate container with water level indicator
8 Air inlet grille with air filter
9 Back housing panel
10 Connection for condensate drainage hose
11 Castor
12 Mains cable
Description of the control panel (Fig. 2)
W.F.: The ”Condensate container full” indicator lights
up red whenever the condensate container is full.
RH 40%...RH 70%: The ”Adjustable room humidity”
indicator lights up green as soon as the range has
been selected and the appliance is switched on.
Power: This lights up red as soon as the mains
voltage is present and then lights up green when the
appliance is switched on.
Pressure switch (A): For setting the functions
On/Off/Room humidity.
Technical data
Power supply: 230 V ~ 50 Hz
Max. rated current consumption: 1.8 A
Starting current: 7.5 A
Max. power consumption: 400 W
Sound pressure level: ≤ 48 dB(A)
Dehumidifying capacity:
0.8 l/h (at a room temperature of 30°C and air
humidity of 80%)
0.5 l/h (at a room temperature of 27°C and air
humidity of 60%)
Operating range for humidity 40-80%
Operating range for temperature: 8 -32°C
Max. air flow volume: 180 m
3
Volume of condensate container: 5.3 liters
Coolant: R134a
Coolant quantity: 170 g
Appliance dimensions: 340 x 540 x 260 mm
Appliance weight: 15.5 kg
Features
Once the predefined room humidity has been
reached the integrated compressor in the appliance
switches off automatically. The fan continues running
so that the air humidity in the room can be
monitored. The compressor switches on again
automatically whenever the predefined air humidity in
the room is exceeded. The appliance then switches
off automatically when the condensate container is
full. Provision has also been made for the
condensate to be drained off permanently if required.
Operating principle
The dehumidifier controls the relative humidity of the
inlet air. The humid air condenses on the cooler
elements and is transferred to the water tank. The
dry air is heated a little on the condenser and
returned to the room.
Scope of use
The dehumidifier is designed for private use only
(e.g. for living rooms, bedrooms, bathrooms,
storage areas, laundry rooms or cellars).
GB
7
Condensor
Evaporator
Compressor
Condensed
water tank
Humid
air
Dry air