EasyManua.ls Logo

EINHELL TE-CF 18 Li - Troubleshooting

EINHELL TE-CF 18 Li
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
- 20 -
11. Troubleshooting
Suspected malfunctions are often due to reasons which the user can rectify himself/herself. You should
check the machine therefore on the basis of this section. You can solve the problem quickly in most ca-
ses.
PROBLEM POSSIBLE CAUSE SOLUTION
Brewing operation fails to start - The battery is not correctly
connected
- The battery is empty
- Connect correctly
- Charge the battery
The machine does not perform
on its highest level
- Battery performance is too low
- The battery is coming to the
end of its working life
- The water tank is empty
- The heating element is
defective
- Charge the battery
- Replace the battery
- Fill the water tank
- Arrange for repair by an autho-
rized service center
Water runs out of the water tank - The water tank has been
over lled
- Observe the recommended
quantity of water
Water runs out of the lter
holder
- Too much co ee powder is
being used
- Too many co ee pads have
been inserted
- The co ee pads have been
wrongly positioned
- The co ee powder has been
grounded too nely
- The co ee powder has been
compacted too rmly
- Reduce the quantity of co ee
powder
- Put in the correct amount
- Place the co ee pad in the l-
ter holder as described in the
section “Brewing”
- Use a coarser degree of grin-
ding instead
- Fill in more loosely
Anl_TE_CF_18_Li_SPK13.indb 20Anl_TE_CF_18_Li_SPK13.indb 20 31.07.2023 14:09:3931.07.2023 14:09:39