Secure the agitator horizontally and lift only by the provided screw, avoiding unilateral forces on the propeller.
Install a 30 mA RCD to disconnect all power circuits in case of a fault.
Motor thermal contacts and a phase-sensitive protection switch ensure reliable shut-down due to overheating.
Disconnect electrical system, protect against re-energization, ensure no explosive atmosphere, and use qualified personnel.
Replace mechanical seals after 3000 operating hours or 2 years; never reinstall removed seals.
Check circuit breakers, fuses, and motor overload/cooling issues; eliminate cause and cool down before restarting.
If lamp illuminates, change oil; if it relights, outer mechanical seal is likely defective and requires specialist repair.
Take explosion protection seriously, observe regulations, disconnect power, discharge windings, and avoid sparks.
Processed fluids can form toxic/explosive gases; ensure ventilation, prohibit smoking/naked flames, and observe association specs.