1. INTRODUCTION

Product Overview and Indications

Intended use, delivery routes, and types of solutions the pump can deliver.

Dedicated Delivery Mode Configurations

How pump types are preconfigured for specific delivery modes for safety and convenience.

Features

Key features designed to simplify treatment and ensure patient safety.

Safety and Compliance Information

Overview of labeling, safety, and compliance information.

Warnings and Safety Precautions

Important safety information and precautions for operating the Sapphire pump.

2. COMPONENTS, ACCESSORIES, AND ADMINISTRATION SETS

Unpacking the Pump

Items included with the Sapphire pump and steps for inspection.

Hardware and Software Components

Identification and description of the pump's hardware and software components.

Touch Screen

Explanation of the pump's touch screen areas and their functions.

Using Pump Accessories

Instructions on setting up various pump accessories like cradles and lockboxes.

PCA Lockboxes

Purpose and workflow for using PCA Lockboxes of different capacities.

PCA;PCEA;PIEB Bolus Handle

Functionality and connection of the remote bolus handle for patient-controlled boluses.

Power Supply

Specifications and charging procedures for the pump's power supply.

External Battery Pack

Critical warnings and safety precautions for using the External Battery Pack (EBP).

Multi-Pump Mounting System

System designed to facilitate the use of multiple pumps and provide power consolidation.

Administration Sets

Information on using Q Core approved administration sets and alternatives.

Q Core Approved Administration Sets

List of administration sets approved by Q Core Medical Ltd. for use with the Sapphire pump.

3. FUNDAMENTAL CONCEPTS AND OPERATIONS

Working with the Main Display

Explanation of the pump's main display, its function as a work area, and its components.

Using the Keypad

Details on using the numeric and alphanumeric keypads for data entry and navigation.

Overview of Toolbar Function Keys

Explanation of function keys in the toolbar and their actions on different screens.

Overview of Icons

Description of frequently appearing icons on the Indicators Bar and Main Display.

Selecting Delivery Mode

Explanation of different delivery modes the pump can operate in and how to select them.

Enabling Special Features

How to enable or disable special functions requiring an authorization code.

4. GETTING STARTED

Typical Workflow

Recommended sequence of steps to prepare the pump and administration set for an infusion.

Turning the Pump On

Procedure for powering on the Sapphire pump and system checks.

Turning the Pump Off

Steps for powering off the pump, including emergency shutdown.

Connecting the Infusion Container to the Administration Set

Steps for connecting the infusion container to the administration set, including safety precautions.

Opening the Safety Door

Procedure for opening the pump's safety door to access the administration set.

Inserting the Administration Cassette

Step-by-step instructions for inserting the Q Core administration cassette into the pump.

Removing the Administration Cassette

Procedure for safely removing the Q Core administration cassette from the pump.

Automatic Priming Using the Pump

Procedure for priming the administration set using the pump's automatic function.

Priming Manually

Instructions for manually priming the administration set using gravity or the AFFV.

5. USING THE DELIVERY MODES

Continuous Mode

Operating the pump in Continuous Mode, including parameters and mid-infusion actions.

Multi-step Mode

Operating the pump in Multi-step Mode, including parameters and mid-infusion actions.

Total Parenteral Nutrition (TPN) Mode

Operating the pump in TPN Mode, including parameters and mid-infusion actions.

Intermittent Mode

Operating the pump in Intermittent Mode, including parameters and mid-infusion actions.

Patient Controlled Analgesia (PCA) Mode

Operating the pump in PCA Mode, including parameters and mid-infusion actions.

Epidural Mode

Operating the pump in Epidural Mode, including PCEA and Epidural Intermittent sub-modes.

6. BASIC INFUSION OPERATIONS

Starting New Infusions: Shortcuts

Shortcut operations to begin an infusion without re-entering parameters.

Resuming Infusions After Pump Shutdown

Procedure for resuming an infusion after the pump has been turned off.

Mid-infusion Actions

Common procedures performed during an infusion, such as pausing or aborting.

7. OPTIONS MENU: CONFIGURING, VIEWING AND TESTING

Main Options: Overview

Overview of the Options screen for accessing configurable pump settings, testing, and system data.

Setting Delivery Mode

How to change the pump's delivery mode using the Options menu.

Managing Configuration Settings

Viewing and updating pump configuration settings like alarms and audio.

Testing System Function

Testing basic system functionalities of the pump, accessible by High or Technician users.

View Menu

Accessing current pump settings and lists of audited events.

Viewing System Parameters

Viewing current system settings and infusion parameters, and updating selected settings.

Viewing the Event Log

Viewing a record of all events audited by the system, by date or all events.

Viewing Delivery History

Summary of medication delivery and bolus events for PCA, PCEA, and PIEB modes.

Using Special Mode Options

Viewing and updating PCA-specific parameters like bolus rate and infusion type.

8. USING ADVANCED FEATURES

Managing Authorization Levels

Setting authorization levels to control access to pump programming options.

Password Re-entry

Requirement to re-enter password for specific actions to prevent inadvertent changes.

Creating and Editing PreSet Programs

Creating, editing, and deleting infusion programs with predefined parameters.

Using the Set Delay Feature

Programming an infusion to start in advance or to set it to Standby.

Using the New Patient Feature

Associating infusions with a specific patient to track data.

Monitoring the Accumulated Volume Infused (Shifts Total)

Monitoring the cumulative volume infused for a specific patient.

9. DRUG LIBRARY

Overview

Information about customized drug groups and Clinical Care Areas (CCAs) for safer practice.

Clinical Care Area (CCA)

Information about CCAs, drug profiles, and their accommodation capacity.

Changing a CCA

Procedures for selecting or changing the CCA, and how it applies during operation.

Programming a New Infusion with the Drug Library

Steps for programming infusions using the Drug Library, including drug name entry and profile selection.

Soft Limit

Understanding soft limits and how the pump alerts users to exceed recommended parameter ranges.

10. ALARMS AND TROUBLESHOOTING

Alarms Overview

Description of different types of alarms and their effects on the infusion.

Level 1 Alarms

Highest severity alarm category where the pump shuts down and infusion stops.

Level 2 Alarms

High severity alarm category where infusion stops and requires technician reactivation.

Level 3 Alarms

Medium severity alarm category requiring attention; infusion stops but may be resumed.

Messages

Indicates medium severity conditions requiring attention; infusion continues.

Troubleshooting

Common programming issues and solutions for the Sapphire pump.

11. MAINTENANCE AND STORAGE

Cleaning and Disinfecting the Pump

Procedures for cleaning and disinfecting the pump and its components.

Reprocessing the pump when used by a single patient multiple times

Procedures for cleaning and disinfecting the pump for single patient, multiple use.

Preventive Maintenance

Guidelines for routine inspection, maintenance tasks, and alarm testing.

Battery Care Information

Information on battery charge levels, operation time, and replacement recommendations.

Charging the Battery

Procedure for charging the pump's battery before initial use and during storage.

Battery Maintenance

Procedures to promote maximum battery life through regular maintenance.

Transport and Storage

Conditions and guidelines for transporting and storing the pump and its components.

12. TECHNICAL SPECIFICATIONS

Pump Accuracy

Graphs and conditions for testing pump accuracy according to IEC standards.

Pump Specifications

Detailed table listing pump dimensions, weight, mechanism, modes, KVO rate, accuracy, etc.

Start-up and Trumpet Graphs

Graphs representing startup flow, stability, and flow rate deviation over time.

Environmental Specifications

Operating and storage conditions related to temperature, humidity, and pressure.

Electromagnetic Compatibility Statement

Information about testing and recommendations for electromagnetic emission and immunity.

13. LIMITED WARRANTY

Parties Covered by this Warranty

Specifies that the warranty extends only to the Initial Buyer of the Sapphire.

Warranty Performance Procedure

Procedure for making a defect claim, including contact information and return authorization.

Conditions of Warranty

Conditions that void the warranty, such as unauthorized repair or misuse.

Limitations and Exclusions

Exclusions, disclaimers, and limitations of the manufacturer's warranty obligations.

Service Information

Guidelines for service and repair, including return authorization and packing instructions.

Technical Support Contacts

Contact information for technical assistance and support.

Eitan Sapphire Multi-Therapy Specifications