ELECTRONIC THERMOREGULATOR NHC-56M
TECHNICAL DESCRIPTION
OPERATION MANUAL
TERMOREGULATOR ELECTRONIC NHC-56M
DESCRIERE TEHNICĂ
INSTRUCŢII DE EXPLOATARE
ЭЛЕКТРОННЫЙ ТЕРМОРЕГУЛЯТОР NHC-56M
ТЕХНИЧЕСКОЕ ОПИСАНИЕ
ИНСТРУКЦИЯ ПО ПРИМЕНЕНИЮ
ELEKTRONISCHE THERMOSTAAT NHC-56M
TECHNISCHE BESCHRIJVING
GEBRUIKSAANWIJZING
ELEKTRONISCHER TEMPERATURREGLER NHC-56M
TECHNISCHE BESCHREIBUNG
GEBRAUCHSANLEITUNG
RÉGULATEUR THERMORÉLECTRONIQUE NHC-56M
DESCRIPTION TECHNIQUE
MODE D’EMPLOI
EN
NL
RO
2
2
6
FR
1
DE
8
NHC-56Mv210215
4
0
2
RU
2
3
CENTRALINA ELETTRONICA DI RISCALDAMENTO NHC-56M
DESCRIZIONE TECNICA
ISTRUZIONE DI USO
IT
8
3
Question and Answer IconNeed help?

Do you have a question about the Eldom Invest NHC-56M and is the answer not in the manual?

Summary

Technical Description

Operation Modes

Lists and explains different operational states of the thermoregulator, such as Standby, Heating, and Smart Control.

Error Messages

Details various error codes and their meanings for troubleshooting, including issues like wrong time or faulty components.

Operation With Thermoregulator

Settings in the Main Menu

Configuration options accessible via the main menu, including time, language, display, timers, tariffs, and system setup.

System Setup

Configuration for weekly programmer, heating element power, water heater volume, and Anti-Legionella function.

Smart Control Settings

Advanced settings for automatic temperature selection, energy saving, and water consumption optimization.

Temperature Setting

Adjusting the desired water temperature for the thermoregulator, with a specified range and adjustment method.

Operation Modes

Standby Mode

Turns off active operations while retaining Frost protection and Delayed Start options.

Heating Mode

Maintains the user-set temperature, activating the heating element when temperature drops by 4 degrees.

Self-learning Mode

Records water usage for a week to enable energy savings in Smart Control mode.

Smart Control Mode

Automatic temperature selection for lowest electricity cost, with options for Low Cost Tariff, Schedule of use, or EN 814.

Timers and Delayed Start

Mode Timers

Controls water heating algorithm using a weekly programmer for scheduling heating element activation and temperature.

Delayed Start Mode

Enables automatic switching on of the appliance from Standby mode at a user-defined future time.

Information Screens and Functions

Information Screens

Displays electricity consumption meters, WiFi status, software version, and smart info about water heater operation.

Frost Protection

Activates heating element when water temperature drops to 3°C or below to prevent freezing.

Anti-Legionella Function

Heats water to 70°C if not heated for 7 days, typically activated during the Low Cost tariff period.

Eldom Invest NHC-56M Specifications

General IconGeneral
MountingDIN rail
Operating voltage230 V AC
Temperature Control Accuracy±1°C
Sensor typeNTC
Protection classIP20
Weight150 g
Power Consumption2 W
TypeElectronic
Maximum load16A
Temperature Range-50°C to 110°C
Temperature Setting Range-50°C to 110°C
Hysteresis1°C to 10°C adjustable