Positioning
Your heater should be horizontally or vertically sited allowing su cient
space for pipe connections and wiring, it should be screw  xed securely to
a  rm base or wall.
NOTE: See  gure 2 for details of the foot arrangement when securing
to the wall or  oor.
The heater should be installed at a low point in the  ltration system.
It should be positioned downstream (after) of the  lter and upstream
(before) of any dosing or other water treatment plant. (see  g.3)
NOTE : If the  ow direction is reversed (explained later in this
booklet) the heater must remain sited after the  lter.
Factory set  oor
mount ‘Foot position
To reset for wall
mount option,
undo the bolts and
re-assemble in the
vertical position as
shown.
Floor mount ‘Foot position’
Wall mount ‘Foot position’
Fig 2.
ENGLISH