Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O-Convect - Touchline
Quick Installation Guide
Rev: B - 12/11/2018
Question and Answer IconNeed help?

Do you have a question about the Electrolux Air-O-Convect and is the answer not in the manual?

Electrolux Air-O-Convect Specifications

General IconGeneral
BrandElectrolux
ModelAir-O-Convect
CategoryOven
LanguageEnglish

Summary

Information

Attention

Read instructions, follow local codes, and contact service for installation issues.

Water Connection

Connect to adequate filtered potable water supply and ensure proper wastewater disposal.

Electrical and Gas Connection

Ensure supply complies with rating plate, use dedicated, earthed source with isolation switch.

Installation

Chloride Test

Test water chloride levels using titrator; failure to install correct system voids warranty.

Total Dissolved Solids (TDS) Test

Measure water TDS using meter, display shows results in PPM (parts per million).

Filtration System

Determine water filter needs (BWT/RO) based on Chloride and TDS test results.

Positioning

Install under extraction canopy; maintain 500mm (heat) / 300mm (non-heat) clearances.

Drainage Connection

Connect drain kit to tundish; ensure minimum 300mm clearance and correct pipe seating.

Detergent Tray (6 Grid, 10 Grid)

Connect detergent tray, rinse aid (blue) to left, oven cleaner (red) to right compartment.

Oven Cleaner Connection (20 Grid)

Connect rinse aid (blue) to left and oven cleaner (red) hoses directly to their respective bottles.

Water Connection

Details filtered (CWI-1) and unfiltered (CWI-2) water connections, pressure, and flow rates.

Electric Oven - Power

Wire electric ovens to supply via licensed technician; requires isolation switch and earthed source.

Gas Oven - Power

Connect gas ovens to supply via licensed technician; requires isolation valve and correct gas connection.