REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12)
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED"
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN"
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
REFRIGERATOR
LIGHT S
FREEZER
LIGHTS
NEUTRAL
FZR DOOR SW. SENSE
NEUTRAL
LINE
VEE
COMM
GROUND
J9A-1
ASSY_OU T
ASSY__IN
+5V
GROUND
+5V
RESET_ FLASH
BKGD / MSJ
GROUND
JF-4
JF-3
JF-2
JF-1
J8-8
J8-7
J8-6
J8-5
J2-1
J3-1
J3-2
J4A-14
J4A-13
J4B-5
J4A-7
J4B-6
J4B-1
J4B-2
J4B-3
J4A-3
J4A-9
J4A-5
J4A-11
NTC - AMBIENT
LINE
G5LE RELAY
J2-1
NTC - FZR
NTC - FF
DAMPER
MOTOR
REFRIGERATOR
CONTROL
LINE
J2-12
J3-8
J2-6
J1-1
J3-9
J1-3
(+12 )
VCC(+12)
VS
COM
FG
M
M
NEUTRAL
DEFROST THERM.
DEFROST HEATER
M
OUT 1A
OUT 2A
OUT 1B
OUT 2B
UI A
J9A-3
J9A-2
CONDENSER FAN
VCC
COMPRESSOR
DC EVAPORATOR FAN
ISOLATED
ERF2500++ ERROR CODES:
FREEZER DISPLAY:
"OP" OR "2" - FREEZER THERMISTOR "OPEN"
"SH" OR "3" - FREEZER THERMISTOR "SHORTED "
FRESH FOOD DISPLAY:
"OP" OR "2" - FRESH FOOD THERMISTOR "OPEN "
"SH" OR "3" - FRESH FOOD THERMISTOR "SHORTED"
BOTH DISPLAYS:
"SY CE" - COMMUNICATION ERROR
"SY CF" - COMMUNICATION LOST ERROR
"SY EF" - EVAPORATOR FAN ERROR
NEUTRAL
ICE MAKER
FILL VALVE
FZ ICE MAKER OUTPUT
MULLION HEATER
FREEZER ICE MAKER
J3-3
J3-4
LINE
IM WATER SENS E
J3-9
J3-6
LINE (PTD)
ERF2500++
REFRIGERATOR DOOR OPENING IS DETERMINED
BY MAGNETIC SWITCH ON USER INTERFACE
J3-10
J3-11
J1-3
J1-4
J1-1
LED POWER
BOARD
Variable Capacity Compressor (VCC) Diagnostics (select models)
If test 38 fails, diagnose as follows:
Replace Inverter Board
→ Check at Inverter Board on
Compressor
(BLK and RED wires)
Is Inverter Board receiving 10-15
VAC and 1-5 VDC from Main
Control Board?
→ Check at Main Control Board
(BLK/WHT and RED/BLK wires)
Is Main Control Board sending
10-15 VAC and 1-5 VDC to
Inverter Board?
no
→ Check at the connector from the power cord
harness into the inverter board, located in
the machine compartment.
(PUR and WHT wires)
Is Inverter Board receiving 115 VAC
from power supply?
• Check voltage supply.
• Check and repair power
cord harness wiring and
connections.
no
Identify and repair damaged wires or
poor connections between Main Control
Board and Inverter Board.
yes
→ Remove inverter box from the
compressor and check resistance
across compressor winding pairs as
shown.
Is resistance across all winding
pairs equal?
Replace Compressor and
Inverter Board.
no
→ Check connections from Inverter
Board to Compressor
Are connections from Inverter
Board to Compressor intact?
yes
Identify and repair damaged
wires or poor connections
between Inverter Board and
Compressor.
no
VCC Resistance Check
Check resistance between terminals 1 and
2, 2 and 3, 3 and 1.
If all resistances are equal,
compressor is operative.
Replace Main Control Board.
no
yes yes
yes