PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°
CONTROL SETTING (2500
++
CONTROL)
Variable Speed Compressor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 to 40% 100%
Freezer Temperature
-6° to 6°F
-21° to -14°C
-6° to 6°F
-21° to -14°C
Refrigerator Temperature
33° to 46°F
0.5° to 8°C
33° to 46°F
0.5° to 8°C
Low Side Pressure
(cut-in)
5 to 12 psig
34 to 83 kPa
N/A
Low Side Pressure
(cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure
85 to 95 psig
586 to 655 kPa
120 to 135 psig
827 to 931 kPa
Wattage 40 to 55 60 to 70
Amps (running) 0.5 to 1.1 0.7 to 0.9
Base Voltage 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Cabinet Size
Thermostat Heater
Cut-in Cut-
out
Watts Ohms
23’ SD, 28’ SD, 23’ CD
25°F
(-4°C)
47°F
(8°C)
500 26
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
3.1
(Energy Star, some models)
1100 CW
Opposite Shaft
0.03 Running
FREEZER ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F (9°C), Closes at 15°F (-9°C)
Heater Voltage 115 vac
FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1 Green / Yellow Ground
2 Yellow Water Valve
3 Black Line
4 Light Blue Neutral
CAUTION
All electrical parts and wiring must be shielded from torch flame. DO
NOT allow torch to touch insulation; it will char at 200°F and flash ignite
(burn) at 500°F. Excessive heat will distort the plastic liner.
SERVICE DATA SHEET
242199300
FREEZER ICE MAKER - AUTOMATIC DEFROST
BOTTOM FREEZER - R134a
System Diagnostic Mode
Activate:
Press FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously.
Press FF UP to advance through tests.
Deactivate:
Press FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of
inactivity. Note: Silence alarm.
• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,“off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air ow as appropriate to determine results of tests.
Test To activate test: Passing result
-- First Screen -- All LED lights on UI illuminated
-- Second Screen -- All segments on UI temperature displays illuminated
-- Third Screen -- Blank UI display, no lights illuminated, no shadowing; “-” and “+”
blinking on FF display side to show location.
28 Dispenser Paddle Press disp. paddle “on” on UI when depressed; “off” when released
1* Standard
Compressor
Press power on-off Compressor running when “on”; stopped when “off”
2 Defrost Heater Press power on-off Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.
3 FF Light Press power on-off With FF door open, FF lights on when “on”; off when “off”
8 Water Valve
(Dispenser)
Press power on-off FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off
9 FZ Light Press power on-off With FZ door open, FZ lights on when “on”, off when “off”
10 Auger Motor Press power on-off FF door must be closed.
Motor running when “on”; motor stopped when “off”
11 Cube/Crush
Solenoid
Press power on-off FF door must be closed. Do not leave solenoid in activated state.
Solenoid activated when “on”; deactivated when “off
41* Perfect Temp Drawer
(PTD)
Press power on-off PTD UI illuminated when “on”, off when “off”
12* VCC Condenser Fan Press power on-off Fan running when “on”; stopped when “off
38* VCC Compressor Press power on-off Compressor running when “on”; stopped when “off”
15 Evaporator Fan Press power on-off Fan running for minimum of 10 sec. when “LO” or “HI”; stopped when
“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.
22 Damper Press power on-off With inspection mirror, observe damper open when “OP”; closed when “CL
23 FF Door Open/close FF door “CL” on UI when door closed; “OP” when open
24 FZ Door Open/close FZ door “CL” on UI when door closed; “OP” when open
26 Defrost Limit Switch Activates automatically “CL” on UI when closed; “OP” when open
36 Ice Chute Door Depress ice chute door
or press power on-off
“OP” on UI when manually opened; “CL” when closed. Or, using “power on-
off”, “OP” on UI when solenoid activated, “CL” when deactivated
29 FF Thermistor Mid-
level
Activates automatically UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short
30 FZ Thermistor Activates automatically UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
“OP” if open; “SH” if short
33 Ambient Thermistor
@ Main Board
Activates automatically UI shows temperature sensed at main board; pass if within +20°F/-10°F of
temperature measured with gauge at main board location.
“OP” if open; “SH” if short
35* FF Thermistor
Upper-Level
Activates automatically UI shows temperature sensed by upper level FF thermistor; pass if within
10°F of temperature measured with gauge at upper-level FF thermistor loca-
tion. “OP¯” if open; “SH¯” if short
34* Ambient Thermistor
@ UI
Activates automatically UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
ture measured with gauge at UI location. “OP” if open; “SH” if short
0- Firmware
Parameters
Press power on-off Displays digit sequence; record
2- Main Board
Firmware
Press power on-off Displays digit sequence; record
4- UI Firmware Press power on-off Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualied repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.
Error Codes Special Modes
Display
Interpretation Mode
Display Activate/Deactivate
(press for up to 10 sec. simultaneously)
FZ FF FZ FF
-- OP Open FF Thermistor Manual Defrost d F FF UP and FF DOWN / same to deactivate
OP -- Open FZ Thermistor Display / Showroom 77 77 FZ UP and FF DOWN / Power-on-Reset
(POR)
-- SH Shorted FF Thermistor Sabbath Sb Sb FZ DOWN and FF UP / same to deactivate
SH --
Shorted FZ Thermistor System Diagnostic No FF or FZ display,
all UI LEDs on.
FZ UP and FZ DOWN / FF UP to deactivate
SY CF
UI to Main Control
Board communication
failure; on start up
Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.
Contact TID before replacing main control board.
• Refer to Service Manual for additional information.
SY CE
UI Main Control Board
communication error;
after a period in operation
SY EF Evaporator Fan Failure
FREEZER ICE MAKER INFORMATION
(Where Applicable)
Test Cycling: Remove cover by inserting screwdriver in notch at bottom and pry-
ing cover from housing. Use screwdriver to rotate motor gear counterclockwise until
holding switch circuit is completed. All components of ice maker should function to
complete the cycle.
Water Fill Volume: The water fill adjustment screw will change the fill time.
One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to
4.3 oz.). When a water valve is replaced, the fill volume must be checked.
T
U
R
N
Mounting
Plate
Screws
Mounting
Plate
Screw
Motor
Gear
Timing
Gear
Water Fill
Adjustment
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.
POWER
ICE MAKER
I
CE MAKER
ICE MAKER
WATER VALVE
LINE
THERMAL
CUT-OUT
HOLD
SWITCH
THERMOSTAT
SHUTOFF
SWITCH
WATER FILL
SWITCH
MOLD HEATER
MOLD
MOUNTING
PLATE
165 WATTS
MOTOR
NEUTRAL
BLK
BLK
BLK
BLU
C
C
C
NO
NO
NO
NC
NC
NC
YELLOW
BRN
RED
GRN / YEL
RED
RED
LT. BLUE
P-3
P-1
P-2
P-4
ICE MAKER
LT. BLUE

Other manuals for Electrolux EI23BC30KS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electrolux EI23BC30KS and is the answer not in the manual?

Electrolux EI23BC30KS Specifications

General IconGeneral
Typefreestanding
Stylefrench door
Colorstainless steel look, stainless steel
Refrigerator Capacity22.6 cubic feet
Freezer Capacity6.9 cubic feet
Humidity Controlled Crispersyes
Defrost Systemautomatic
Number of Refrigerator Door Binsyes
Temperature Controldigital
Interior Lightled
Ice Makeryes
Water Filteryes
Smart Homeno
Annual Energy Consumption489 kilowatt hours
Current8.5 amperes
Weight and Dimensions IconWeight and Dimensions
Depth28.19 inches
Height69.5 inches
Width36 inches
Net Weight365 pounds