installation instructions 3
EJectrical connection (non-Canada} o4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing
could result in personal injuryor even death.
-- Neutral
IWH ITEwire)
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block
access cover in the lower corner on the back of
the dryer.
3. Install a UL-approved strain relief according
to the power cord/strain relief manufacturer's
instructions Anthe power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30
amp. power cord, NEMA 14-30 type ST or
SRDT, through the strain relief.
5. Disconnect the internal (WHITE) dryer harness
ground wire from the (GREEN) ground screw
next to the terminal block.
6. Attach the ground (GREEN) power cord wire
to the cabinet with the ground (GREEN) screw.
Tighten the screw securely.
7. Move the internal dryer harness ground
(WHtTE) wire to the terminal block and attach
it along with the neutral (WHITE) power cord
wire conductor to the center, SILVER colored
terminal on the terminal block. Tighten the
screw securely.
8. Attach the RED and BLACK power cord
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws secu rely.
ELECTRICAL SHOCK HAZARD
Do not make a sharp bend or crimp wiring!
conductor at connections.
blod<
Une2
(BP_L_$terminal)
Neutral
{SILVERterminal)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
Move internal ground (WHITE)
wireto neutral(SILVER) ,_
terminal for4-wire system. -_,_
GREEN
ground screw
Neutral
terminal
9. Fotlow manufacturer's guidelines for firmly
securing the strain relief and power cord.
10. Reinstall the terminal block cover.
GREEN
ground wi_
BLACK
or RED
power wire
BLACKer
RED power wire