18 www.electrolux.com
$O©NOT©SUBJECT©THE©MAINS©CABLE©TO©
force.
4HE©DISTANCE©BETWEEN©THE©UNIT©AND©
heat sources is at least 1.5 m.
5SE©AN©AIR©SWITCH©4HE©AIR©SWITCH©MUST©
have functions for magnetic tripping
and heat tripping to prevent short
circuit and overload. The suitable
capacity is specified in the following
table.
NOTE
-AKE©SURE©THAT©THE©LIVE©WIRE©THE©
neutral wire and the ground wire
in the mains socket are properly
connected.
)NADEQUATE©OR©INCORRECT©ELECTRICAL©
connections can cause electric shock
or fire.
Grounding requirements
4HE©UNIT©IS©A©TYPE©)©ELECTRICAL©
appliance. Make sure that the unit is
properly grounded.
4HE©YELLOWGREEN©WIRE©IS©THE©GROUND©
wire that cannot be used for other
purposes. Improper grounding can
cause electric shock.
4HE©GROUND©RESISTANCE©MUST©COMPLY©
with local regulations.
4HE©MAINS©SUPPLY©MUST©HAVE©RELIABLE©
ground terminal. Do not connect
the ground wire to water pipes, gas
pipes, contamination pipes or other
possible unsafe places.
&USES©MUST©COMPLY©WITH©THE©
prescribed model and rating printed
on the fuse cover or circuit board.
Air conditioner (Btu) Air switch capacity
09-12K 16A