21
GLMB209DBB
GLMB209DSB
GLMB209DQB
PLMB209DCC
NOISE FILTER UNIT
NOISE SUPPRESSION COIL
LINE CROSS CAPACITOR
RESISTOR
LINE BYPASS CAPACITOR
LINE BYPASS CAPACITOR
0.0033uF/ 250v
0.0033uF/ 250v
LOAD
LOAD
H
N
MONITOR
FUSE
3) Power Source Circuit
This circuit generates voltages necessary in the control
unit from the AC line voltage.
In addition, the synchronizing signal is available in order
to compose a basic standard time in the clock circuit.
Symbol Voltage Application
VSS -5V LSI(IC1)
4) Relay Circuit
A circuit to drive the magnetron, fan motor, turntable
motor and light the oven lamp.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (key touch sound and completion sound).
6) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It accompanies a very small error because it
works on commercial frequency.
7) Door Sensing Switch
A switch to “tell” the LSI if the door is open or closed.
8) Back Light Circuit
A circuit to drive the back light (Light emitting diodes LD1-
LD4).
9) Absolute Humidity Sensor Circuit
This circuit detects moisture of the cooking food to allow
its automatic cooking.
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1) Key Unit
(2) Control Unit (The Control Unit consists of Power Unit and
LSI Unit).
The principal functions of these units and the signals commu-
nicated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in the
LSI are sent to the key unit through P20-P27.
When a key pad is touched, a signal is completed through the
key unit and passed back to the LSI through P70, P71, P41,
P45, P47 and AN3 to perform the function that was re-
quested.
Control Unit
Control unit consists of LSI, reset circuit, indicator circuit,
power source circuit, relay circuit, buzzer circuit, synchroniz-
ing signal circuit and back light circuit.
1) Reset Circuit
This circuit generates a signal which resets the LSI to the
initial state when power is supplied.
2) Indicator Circuit
This circuit consists of 22 segments and 3 common
electrodes using a Liquid Crystal Display.
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the leads to the primary of the power transformer.
5. Using an ohm-meter, check between the terminals as described in
the following table
MEASURING POINT INDICATION OF OHM-METER
Between N and H Open Circuit
Between terminal N and LOAD Short Circuit
Between terminal H and LOAD Short Circuit
If incorrect readings are obtained, replace the noise filter.
6. Reconnect all leads removed from components during testing.
7. Re-install the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
O NOISE FILTER TEST