Problem Possible cause Solution
The temperature in the
appliance is too low/too
high.
The temperature regulator
is not set correctly.
Set a higher/lower tempera‐
ture.
The food products' tem‐
perature is too high.
Let the food products tem‐
perature decrease to room
temperature before storage.
The FastFreeze function
is switched on.
Refer to "FastFreeze func‐
tion".
If the advice does not lead to
the desired result, contact
the nearest Authorised
Service Centre.
7. INSTALLATION
WARNING!
Refer to Safety chapters.
7.1 Positioning
This appliance can be installed in a dry,
well ventilated indoor where the ambient
temperature corresponds to the climate
class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
7.2 Electrical connection
Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
The manufacturer declines all
responsibility if the above safety
precautions are not observed.
This appliance complies with the
E.E.C. Directives.
7.3 Installation of the appliance
and door reversal
Please refer to separate
instructions on installation
(ventilation requirements,
levelling) and door reversal.
8. TECHNICAL DATA
Height 1544 mm
Width 595 mm
Depth 668 mm
Rising time 28 h
www.electrolux.com46