Part-No. 323 996 (Englisch) 01/09
Operating Instructions GB
Battery Charger
HS 12/24-30
Charger for 12 V and 24 V lead-acid batteries,
charging current up to 30 A
ELEKTRON-BREMEN GmbH Am Hohentorshafen 17-19 D-28197 Bremen Phone: +49/421/54906906 ·Fax: 5490619
Question and Answer IconNeed help?

Do you have a question about the Electron HS 12/24-30 and is the answer not in the manual?

Electron HS 12/24-30 Specifications

General IconGeneral
Output Voltage12/24V DC
Output Current30A
Charging MethodIUoU
Weight2.5 kg
Battery TypeLead-acid, Gel, AGM
ProtectionShort circuit, Overvoltage, Overtemperature
CoolingFan

Summary

Safety Notes

Electrical Safety

Ensures mains and charging cables are in perfect condition. Contact workshop if damaged.

General Operating Precautions

Read instructions, operate according to them, and ensure good ventilation.

Explosive Gas Hazard

Caution regarding explosive gases generated during charging. Avoid fire and sparks.

Acid Splash Hazard

Wear protective goggles. Wash skin/clothing immediately if acid splashes occur.

Gas Smell Hazard

In case of gas smell, ventilate immediately, do not switch off or remove clips.

Description of the Unit

Unit Compatibility

Suitable for 12/24V wet, maintenance-free gel, fleece, and AGM batteries.

Voltage Selection

The required voltage is selected using the 'charging voltage switch' (1).

Charging Status Indicators

LEDs indicate charging status. Yellow LED (0%) flashes if no battery or contact.

Battery Type Selection

Use switch (5) to select between 2.4 V/cell and 2.35 V/cell for battery types.

Start-up Procedure

Charging Process

Connect clips, select voltage, observe charging indicators, switch off when charged.

Exhausted Batteries

Charger detects and carefully charges exhausted batteries, adjusting current.

Backup Mode Operation

Maintains onboard voltage during battery changes. Requires minimum load current.

Floating Mode

Ensures optimum charging and floating for unlimited periods. Handles discharge.

Fault Indication and Troubleshooting

Fault Indicator (8) Flashing

Indicates overheating or incorrect polarity. Check air outlets/intakes or polarity.

Fault Indicator (8) Steady Light

Signifies a system fault in the charger. Switch off and contact dealer.

Troubleshooting High Voltage

Check battery voltage and set switch (1) accordingly. Fault indicator extinguishes after correction.

Troubleshooting Incorrect Battery

Check battery for defective cells or incorrect charging voltage selection.

Technical Data

Charger Specifications

Details mains voltage, frequency, nominal voltage, constant voltage, and charging current.

Physical and Cable Specifications

Covers protection type, housing dimensions, weight, and cable lengths.