AeroControl/AeroControl-868
The control unit for sun protection systems
General:
The awning controller is a control unit for sun protection systems
(awnings/venetian blinds).
It controls the system connected according to light intensity and
wind strength.
The wind alarm and its signal have precedence over the light
sensor.
The AeroControl-868 controller contains a radio receiver module
set at 868.3 MHz.
Note: Connect the protective earth to the accompanying
terminal block.
You can connect a maximum of 4 AeroControls per
wind sensor.
Operation via:
Momentary contact switch or
hand-held transmitter
(only for AeroControl-868)
3213 LN
N
PE (lloose terminal)
Learn Test
min.
max.
LED green
Radio programming
mode and wind alarm
Wind Light
Exceedance of light value
LED yellow
Exceedance of wind value
DIP
ON
1
3
1
2
Li
GND
GND
Wi N
N
L
Receiver module 868.8 MHz
17 700.6001
Markisensteuerung 28 370.0001
3
1
2
red
Netz
L
PE
N
Markisensteuerung 28 370.0001
3
1
2
GND
Li Wi
GND
NL
N
Jalousietaster
Jalousietaster
Jalousietaster
Markisensteuerung 28 370.0001
WiLi
GND
GND
LN
N
1
3
Venetian blind
Awning
ON
1
Redeployment after wind alarm
No redeployment after wind alarm
PE (lose Klemme)
PE (lose Klemme)
N
PE
L
Netz
PE (lose Klemme)
PE
Netz
N
L
M
1Z
Mains
230VZ
Aero
Aero
1~
M
Ventero
Lumero
Widerstand 10kOhm
M
1~
1~
M
Important safety indications!
Observe the following Instructions.
Danger of injury due to electric shocks.
Connections to the 230 V mains supply must be carried
out by authorized, specialized personnel.
• Check the installations regularly for wear and tear or
damage.
• The regulations stipulated by the local power supply
company should be observed during connection
work, as well as the regulations for wet and damp
areas in accordance with VDE 0100.
• Observe country-specific regulations.
• Only use unaltered elero original parts.
• Ensure that nobody is within the vicinity of the
installation until it is brought to a standstill.
• When carrying out work on the installation
(e.g. maintenance), always disconnect the installation
from the mains supply.
• Keep children away from controls.
• After installation, the control unit must not be
exposed to rain.
Warning!
Connection options:
Aero, Ventero, Lumero,
Mains lead,
1 alternating current drive,
Momentary contact switch
GB