QUICK - GUIDE
REMOTE CONTROL
0 - ON/OFF -
Device on/off.
1 - PUSH-PULL MODE¹ -
24 h operation at the set
speed. Automatic: operation with alternating flow.
2 - SPEED 1¹ -
Low speed setting.
3 - SPEED 2¹ -
High speed setting.
4 - TIMER-SET BOOST² -
Timer-set operation in
ejection only at maximum speed.
5 - SLEEP MODE¹ -
Maintains the selected operating
mode at the set speed 1. To exit this mode before
the end of the 8 hours, press any key (except 0).
6 - FORCED FLOW CONTROL¹ -
The devices operate
either in ejection only or in injection only. Press
once: ejection mode. Press twice: injection mode.
7 - FREE COOLING (no inversion)¹ -
No inversion of
flow. Press once: flow inversion stops in the
direction of rotation active at that moment. Press
twice: all the devices invert flow and maintain this
set direction of rotation.
Thank you for choosing REC-duo. This Quick-Guide helps you to
understand and use your new ventilation system to get the most out
of its performance.
For installation and initial set-up please refer to the main manual.
NOTES
1:
FUNCTION THAT CONTROLS ALL PRODUCTS PAIRED WITH THE REMOTE
CONTROL.
2:
FUNCTION THAT CONTROLS THE SINGLE PRODUCT PAIRED WITH ITS OWN
REMOTE CONTROL
(not valid if only one remote control is used on several devices - see paragraph
"PAIRING A REMOTE CONTROL WITH SEVERAL VENTILATION UNITS").
LED INDICATION:
Every time a button is pressed an LED light on the remote will
indicate that the command has been received.

Other manuals for Elicent REC duo 100

Question and Answer IconNeed help?

Do you have a question about the Elicent REC duo 100 and is the answer not in the manual?

Elicent REC duo 100 Specifications

General IconGeneral
BrandElicent
ModelREC duo 100
CategoryHeating System
LanguageEnglish

Summary

REC duo Remote Control Functions

ON/OFF

Turns the ventilation device on or off.

PUSH-PULL MODE

24-hour operation at set speed with automatic alternating flow.

SPEED 1

Selects the low speed setting for the ventilation.

SPEED 2

Selects the high speed setting for the ventilation.

TIMER-SET BOOST

Timer-set ejection-only operation at maximum speed.

SLEEP MODE

Maintains selected mode at speed 1 for 8 hours, exitable by any key.

FORCED FLOW CONTROL

Operates in ejection-only or injection-only mode. Press once for ejection, twice for injection.

FREE COOLING

No flow inversion. Press once to stop inversion, twice to invert all devices.

REC duo LED Status Indicators

GREEN LED

Indicates extraction mode.

YELLOW LED

Indicates intake mode.

RED LED

Indicates boost with timer active.

FLASHING RED LED

Indicates the filter needs cleaning.

BLUE LED

Indicates MHY operating status.

FADING BLUE LED

Indicates sleep function is operating.

FADING YELLOW OR GREEN LED

Indicates free cooling is active (RC Button 7).

FLASHING YELLOW OR GREEN LED

Indicates forced flow operation (RC Button 6).

FLASHING WHITE/LIGHT BLUE LED

Indicates the remote control command is being received.

FLASHING RED/PURPLE LED

Indicates factory settings are being restored.

PURPLE LED

Indicates LED intensity adjustment.

FLASHING BLUE LED

Indicates speed regulation 1 is active.

FLASHING PURPLE LED

Indicates speed regulation 2 is active.

FLASHING LIGHT BLUE LED

Indicates devices are synchronizing.

FLASHING BLUE WITH EXTENDED SEQUENCE

Indicates synchronization cancellation.

FLASHING GREEN LED (SLAVE)

Indicates a slave unit.

FLASHING GREEN LED (MASTER)

Indicates a master unit.

REC duo Cleaning Instructions