10
MAINTENANCE
CLEANING
To prolong the working life of the device, you must:
1) Clean the pool filter regularly to ensure adequate water flow inside the heat pump.
2) Keep the surface of the coil (evaporator) clean and free from obstructions: paper, leave or other.
3) Clean your unit with mild household cleaner and rinse with a garden hose at low pressure.
WINTERIZING (TITANIUM HEAT EXCHANGER)
When the device is exposed to temperatures below freezing, it becomes essential to prevent ice formation
within the section containing water by draining the heat pump’s heat exchanger. To store your heat pump,
you must:
1) Turn the device off.
2) Turn off the circuit breaker and close the valves.
3) Unscrew the water inlet and outlet connections (Figure A).
4) Rinse the condenser with tap water and drain the system with air pressure or vacuum.
5) Cover the unit with a waterproof drop cloth if left outside all winter.
SEASONAL RESTART
Before restarting your pool heat pump, you must:
1) Check and adjust the quality of the pool water.
2) Make sure the breaker for the heat pump is turned off.
3) Install the heat pump on a level surface and connect all plumbing.
4) Clean the pool filter and ensure that the water return system is working properly.
5) Turn on the circuit breaker for the pool’s heat pump.
WATER BYPASS
Some maintenance operations may require that the pool heat pump be disconnected from the filtration
system. To divert the water, you must:
1. Stop the device.
2. Open the bypass valve and close the water inlet and outlet valves.
For longer stops (1 week or more):
3. Unscrew the water inlet and outlet connections
WARNING
Before any storage or cleaning operation, turn off all electrical circuit
breakers.