Installation Instructions
MATTIRA
Digital Modulating Electric Boilers
MAS15 | MAS18

Questions and Answers

  • M
    Michael NolanAug 14, 2025
    How to troubleshoot Elnur Boiler that will not start?
    • S
      Shawn WrightAug 14, 2025
      If your Elnur Boiler is not starting, first check the incoming power supply. Also, ensure the boiler control switch is turned on. If there was a heating overheat, locate and reset the tripped switch.
  • K
    Kenneth RamirezAug 18, 2025
    What does fault E3 on Elnur Boiler mean?
    • S
      Sharon CooperAug 18, 2025
      If you see the E3 error displayed on your Elnur Boiler, it relates to the heating system water flow switch. Start by checking if the pump is turning freely; refer to section 5.5 for guidance and replace the pump if needed. Ensure to purge the system thoroughly and check that the automatic air valve is open, and vent the pump (sect 5.5). Finally, verify the pump speed is at 3, check the pump duty (sect 4.9b), open all radiator valves, and install a system by-pass, because the system resistance might be too high or there might be a blockage.
  • D
    Danny RiveraAug 21, 2025
    What to do if Elnur Boiler heating system water is discharging from 3 bar safety valve?
    • L
      Lawrence OwensAug 21, 2025
      If the Elnur Boiler system water is discharging from the 3 bar safety valve, it indicates excessive heating system pressure. Check that the filling loop has not been left connected or is letting water pass; disconnect the filling loop hose. Also, verify that the expansion vessel is charged to the correct level with air and check the system expansion volume.
  • T
    tstewartAug 25, 2025
    What does fault E8 on Elnur Boiler mean?
    • E
      elizabeth45Aug 26, 2025
      If your Elnur Boiler displays Fault E8, it indicates a problem with the outdoor temperature sensor, which might be defective or not present. This sensor is optional. Check the connections and replace the sensor if necessary. Also, check if the parameter settings are correct (sect 5.1).
  • L
    Laurie HortonAug 28, 2025
    Why is my Elnur Boiler heating temperature low?
    • A
      Alexander JacobsAug 28, 2025
      If you are experiencing low heating temperature with your Elnur Boiler, verify the temperature and output settings are appropriately selected. Also, check the heating elements for failure and replace them if necessary. Finally, recalculate and reconfigure to see if heat requirements were miscalculated.
  • J
    Joseph LynchAug 31, 2025
    Why the buttons on my Elnur Boiler do not respond?
    • F
      Frank LiAug 31, 2025
      If the buttons on your Elnur Boiler do not respond, it might be because the control panel is blocked. Please refer to Section 6.8, BLOCKING THE CONTROLS, for instructions.
  • D
    Dawn WagnerSep 3, 2025
    How to fix E3 Error on Elnur Boiler?
    • J
      Jennifer EvansSep 4, 2025
      If you see the E3 Error on your Elnur Boiler and need to address system by-pass requirements, ensure the heating system has sufficient water pressure by re-filling it to 1.5bar. Check the pump for circulation issues or seizure, referring to Sect 5.3. Also, closed radiator valves (Thermostatic) may cause the problem. It may be sufficient to maintain one radiator with permanently open valves; however, current Building Regulations recommend fitting an automatic by-pass valve.
  • K
    Kristina BurnsSep 6, 2025
    What does fault E1 on Elnur Boiler mean?
    • H
      harrisonbrandiSep 7, 2025
      If your Elnur Boiler displays fault E1, it indicates an issue with the heating flow temperature sensor. The heating water out temperature probe may be defective, and you should contact Technical Service.
  • M
    Michael CallahanSep 12, 2025
    What does fault E2 on Elnur Boiler mean?
    • K
      Katelyn JohnsonSep 12, 2025
      If your Elnur Boiler displays fault E2, it indicates an issue with the heating return temperature sensor. The heating water return temperature probe may be defective, and you should contact Technical Service.

Summary

2. SAFETY

4. INSTALLATION

4.9 Electrical Connections

Instructions and requirements for electrical connections to the boiler.

Connection to Boiler

Details on connecting the boiler to the mains electricity supply.

5 COMMISSIONING

5.1 Installation Parameters

Procedure for adjusting boiler parameters during installation.

5.2 Limiting Boiler Maximum Output

How to limit the boiler's maximum heat output.

6 OPERATING THE BOILER

6.1 Initial Switching On

Step-by-step guide for the initial power-on of the boiler.

6.2 Control Panel Description

Overview and explanation of the boiler's control panel features.

7 TROUBLESHOOTING

7.1 Possible Faults & Solutions

Common boiler faults and their corresponding solutions.

7.2 Overheat Lock-Out & Re-Setting

Procedure for resetting the boiler after an overheat condition.

7.3 Heating System Flow Switch

Explanation of E3 error related to flow switch and bypass requirements.

7.4 Checking Rated Heat Output

How to check the boiler's configured and modulated heat output.

9 MAINTENANCE & CARE

14. WIRING DIAGRAMS

16 INSTALLATION COMMISSIONING CHECKLIST

17 MAINTENANCE CHECKLIST

Elnur MATTIRA MAS15 Specifications

General IconGeneral
Power Output1500 W
MaterialAluminium
Frequency50/60 Hz
ThermostatYes
Overheat protectionYes
Dry run protectionYes
Indicator lightsYes
TypeElectric
ConnectivityWi-Fi