Installation and Technical Connections
Combi Steamer
Joker B, Joker C 6-23
Article No. 900646 10/05
Place of Installation:
Follow the local regulations and observe the instructions for
the installation of kitchen and shop equipment.
It is mandatory to set up the appliance in horizontal position. True up minor
unevenness with the vertically adjustable feet.
y We recommend to install the ovens on top of original eloma lower
racks/supports or wall brackets. In case of installations on top of worktables,
ensure sufficient stability and load capacity, (weight of an empty oven approx.
100 kg).
The equipment must be secured against tilting and falling down.
y Install no heat or steam sources (for instance deep fat fryers or cooking kettles)
underneath the oven.
Minimum clearance:
y Distance to walls on right, left and back side at least 50 mm. In case of
installations near to materials that risk burning, observe the instructions of fire
protection.
y Avoid to have any other heat and/or steam sources behind or next to the unit.
If this is impossible, ensure sufficient clearance or provide for appropriate
protection. No heat or humidity must penetrate through the cooling slots into the
unit.
Noise Level :
y The emission value of the noise is less than 70 dB/A.
Exhaust air Lrg
y A built-in cooling function cools down water and steam of condensation, which then
runs down the drain. It is therefore not imperative, however recommended, to install
the appliance under a ventilation hood.
y If such a hood is installed, its design and power rates should comply with the
German VDI regulation 2052.
y Connected load 5,9 kW Connected load 3,6 kW
Latent heat emission 3,82 MJ/h 2,33 MJ/h
Sensible heat emission 2,55 MJ/h 1,56 MJ/h
Question and Answer IconNeed help?

Do you have a question about the Eloma Joker B 6-23 and is the answer not in the manual?

Eloma Joker B 6-23 Specifications

General IconGeneral
ModelJoker B 6-23
Power SupplyElectric
Voltage230 V
MaterialStainless Steel
Frequency50 Hz

Summary

Place of Installation

Installation Regulations and Positioning

Follow local regulations, ensure horizontal position, and secure against tilting.

Minimum Clearance Requirements

Spatial Separation for Safety

Maintain 50mm clearance from walls and avoid heat/steam sources nearby.

Noise Level Specification

Noise Emission Limit

The emission value of the noise is less than 70 dB/A.

Exhaust Air and Ventilation

Ventilation Hood Recommendation

Recommended to install under a ventilation hood, complying with VDI 2052 if used.

Electrical Connection and Potential Equalisation

Mains Connection Precautions

Allow unit to acclimatise to room temperature before connecting.

Professional Installation Standards

Connections must be made by an approved electrician according to VDE regulations.

Circuit Breaker and Fuse Protection

Each unit requires its own all-pole circuit breaker and fuse protection.

Energy Optimising Systems

Possibility of connection to energy optimising systems (Model B and C).

Connecting Data Overview

Details on connected load, voltage, and fuse protection for different models.

Water Supply Connections

Drinking Water Connection Standard

Connect to drinking water supply per German standard DIN 1988, section 4.

Water Softener Recommendation

Use water softener for hardness > 6°dH to avoid calcareous deposits.

Required Water Connections

Connect both EWk (soft water) and TWk (hard water) for steam and cooling.

Hose and Service Access

Use pressure-resistant, flexible hose for easy servicing access.

Water Drain Connection

Waste Water System Connection

Connect drain to waste water system per German standard DIN 1986, section 1.

Drain Pipe Material and Design

Use steam temperature resistant pipe, min 40mm diameter, with 5% slope.

Siphon Installation Requirements

Mandatory measures for built-in siphons: pressure relief pipe or open funnel.

Dimensioned Sketch and Technical Data

Appliance Dimensions

Provides overall housing dimensions and connection port locations.

Connection Port Identification

Identifies Lrg, EWk, TWk, EZ, and PE connection points.