EasyManua.ls Logo

ELRO FS1105P - User Manual

ELRO FS1105P
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Importer
ELRO Europe | www.elro.eu
Postbus 9607 - Box E800
1006 GC Amsterdam The Netherlands
Manufacturer:
Siterwell Electronics CO., Limited
No.666 Qingfeng Road, Jiangbei District,
Ningbo, Zhejiang Province, China 315034
Home is not a place, its a feeling
FS1105P
25%
93%
40 m²
0°C
40°C
8 minutes
AC 220-240 V
50 Hz
DE Besuche www.elro.eu
EN Visit www.elro.eu
NL Bezoek www.elro.eu
FR Visitez www.elro.eu
ü
GUARANTEE
DE Montageart: Decke
EN Mounting type: ceiling
NL Montagetype: plafond
FR Type de montage: plafond
ü
ALARM
85dB(A)
at 3 m
DE Betriebstemperatur
EN Operating temperature
NL Bedrijfstemperatuur
FR Temp. de fonctionnement
DE Notfall-batterie (inklusive)
EN Backup battery (included)
NL Back-up batterij (inclusief)
FR Pile de secours (inclusive)
DE Leistungsversorgung
EN Power supply
NL Stroomvoorziening
FR Source de courant
DE Luftfeuchtigkeit bei Betrieb
EN Operating humidity
NL Luchtvochtigheid in bedrijf
FR Humidité de fonct.
DE Optischer Sensor
EN Optical sensor
NL Optische sensor
FR Capteur optique
DE Alarmlautstärke
EN Alarm volume
NL Alarmvolume
FR Volume d'alarme
DE Kapazität
EN Capacity
NL Capaciteit
FR Capacité
DE Alarm Stummschalten
EN Alarm silence facility
NL Alarmsignaal dempen
FR Neutralisation d’alarme
DE Bewohnbare Freizeitfahrzeuge
EN Leisure accommodation vehicle
NL Recreatievoertuig
FR Camping car
9 V
0905
DoP: FS1105P-01
20 FS1105P
EN 14604:2005 + AC:2008
Fire Safety
ESSENTIAL CHARACTERISTICS:
Nominal acvaon condions/ Sensivity, Response delay
(response me) and Performance under fire condion -
Operaonal reliability - Tolerance to supply voltage - Durability of
operaonal reliability and response delay, temperature resistance,
vibraon resistance, humidity resistance, corrosion resistance,
electrical stability
SMOKE ALARM 230 V
RAUCHWARNMELDER 230 V
ROOKMELDER 230 V
DÉTECTEUR DE FUMÉE 230 V
Minimum
Extra
Entree
Content - Inhalt - Inhoud - Contenu Rooms - Zimmer - Kamers - Chambre
WARNING
A.C. POWER
9 V
Min 50cm Min 50cm
XX
0-20°
1/2 1/2
Height - Höhe - Hoogte - Hauteur max. 6m
1 2 3
Roof - Dach - Dak - Toit
0,2m
>
ü ü
X
ü
0,2m
>
Baery - Baerie - Baerij - PileRemove locking plug
Verschlussstecker enernen
Vergrendelingsplug verwijderen
Rerer la fiche de verrouillage
4 6 7
5
9 V
Document nr.: FS1105P_MN | Revision: V9
220-240V AC
~
signal cable
WARNING
A.C. POWER
Acvate - Akvieren - Acveren - Acvé
Live (brown) =
Neutral (blue) =
}
HO7V-U 1.5mm²
WARNING: Turn off the mains power before
installing this alarm to avoid the risk of
electrical shocks.
WARNUNG: Um die Gefahr eines Stromschlags
zu vermeiden, schalten Sie das Stromnetz vor
der Installaon aus.
WAARSCHUWING: Schakel de netspanning
uit voordat u gaat installeren om het risico
op elektrische schokken te voorkomen.
AVERTISSEMENT: Couper l'alimentaon secteur
avant de 'installaon de cee alarme pour éviter le
risque de décharges électriques.
Connect to other devices (max 12)
Mit anderen Geräten verbinden (max 12)
Verbinden met andere melders (max 12)
Connexion à d'autres appareils (max 12)
Mounng on mounng plate
Monteren auf montageplaat
Monteren op montageplaat
Montage sur plaque de montage
1
2
1. Place locking plug
2. Turn on power
1. Verschlussstecker anwenden
2. Einschalten des Geräts
1. Vergrendelingsplug plaatsen
2. Schakel de stroom in
1. Appliquer le verrou
2. Meez l'appareil sous tension
1098
Question and Answer IconNeed help?

Do you have a question about the ELRO FS1105P and is the answer not in the manual?

Summary

Product Specifications

Power and Environmental Conditions

Details power supply, operating temperature, and humidity.

Sensor and Alarm Features

Information on optical sensor, alarm volume, and silence facility.

Mounting Type

Specifies the recommended mounting position for the device.

Installation Guide

Package Contents and Preparation

Check package contents and turn off mains power before starting.

Mounting Placement

Guidance on optimal placement on the roof or ceiling.

Electrical and Battery Connection

Instructions for wiring the AC power and installing the backup battery.

Device Activation

Steps to secure the device and activate it after installation.

Operation and Maintenance

Testing and Cleaning

Procedures for regularly testing and cleaning the smoke alarm.

Hush Functionality

How to temporarily silence the alarm in case of nuisance alarms.

Low Battery Alert

Information on recognizing and responding to low battery warnings.

Operating Modes and Indicators

Explanation of LED signals and acoustic signals for different device states.

Safety and Troubleshooting

Important Safety Warnings

Crucial safety precautions regarding installation and battery replacement.

Symbols and Disposal

Explanation of symbols, recycling, and proper disposal of the product and batteries.

Troubleshooting Common Issues

Guidance on identifying and resolving false alarms and other operational problems.

Summary

Product Specifications

Power and Environmental Conditions

Details power supply, operating temperature, and humidity.

Sensor and Alarm Features

Information on optical sensor, alarm volume, and silence facility.

Mounting Type

Specifies the recommended mounting position for the device.

Installation Guide

Package Contents and Preparation

Check package contents and turn off mains power before starting.

Mounting Placement

Guidance on optimal placement on the roof or ceiling.

Electrical and Battery Connection

Instructions for wiring the AC power and installing the backup battery.

Device Activation

Steps to secure the device and activate it after installation.

Operation and Maintenance

Testing and Cleaning

Procedures for regularly testing and cleaning the smoke alarm.

Hush Functionality

How to temporarily silence the alarm in case of nuisance alarms.

Low Battery Alert

Information on recognizing and responding to low battery warnings.

Operating Modes and Indicators

Explanation of LED signals and acoustic signals for different device states.

Safety and Troubleshooting

Important Safety Warnings

Crucial safety precautions regarding installation and battery replacement.

Symbols and Disposal

Explanation of symbols, recycling, and proper disposal of the product and batteries.

Troubleshooting Common Issues

Guidance on identifying and resolving false alarms and other operational problems.

ELRO FS1105P Specifications

General IconGeneral
BrandELRO
ModelFS1105P
CategorySmoke Alarm
LanguageEnglish

Related product manuals