ems55advanced - Troubleshooting
Quick Guide
User interface
Note: The motion sensor is integrated with the ems controller
(ems55advanced) or remote (ems55Radvanced).
LED indicators
Compressor.
On when the compressor is
running.
Fan.
On when the evaporator fan is
running.
Saving mode
temperature
disable.
On if the saving mode
temperature is disabled.
Motion.
On when motion detected.
Buttons
Set
Up
Defrost
(Starts a manual
defrost)
Down
(Also cancels alarms)
Power up sequence
Checks all the display elements
are working.
Displays the firmware version.
(Example)
Displays the checksum.
(Example)
Normal operation
During normal operation the EMS will display one of the messages
below. If one of the below messages is not displayed the EMS has
registered and alarm or fault.
Ready mode
(Displays USE or temperature)
Saving mode
Defrost mode
Door open
Freeze up protection
If evaporator frozen, ensure appliance sensor is
connected properly. Disconnect appliance sensor and
ensure display shows PF1. Otherwise, replace the
controller.
Alarms and troubleshooting
The EMS controller can display messages to aid fault diagnosis. If an
alarm sounds and the EMS controller displays any of the alarms
below, contact your service provider.
Refrigeration system failure
Condenser high temperature alarm (requires a
condenser sensor)
Appliance sensor failure
Condenser sensor failure (if used)
Evaporator sensor failure (if used)
Over voltage alarm (SHI) or under voltage alarm
(SLO), if used.
Note that the compressor does not run in over or
under voltage conditions.
Door open alarm
Cooler
lights do
not switch
on
If EMS controller is in the ready mode, ensure
that the light switch inside the cooler switched on.
No power
Check for 12 to 13VAC at the rear connector of
the ems controller.

Other manuals for Elstat ems55advanced

Questions and Answers:

Elstat ems55advanced Specifications

General IconGeneral
TypeElectronic controller
Power supply230V AC
Number of relays3
Defrost typeElectric
Input Voltage230V AC
Output Current16A
ApplicationRefrigeration
MountingPanel mount
Protection ClassIP65

Related product manuals