EasyManua.ls Logo

Elto EMA1 - Specifications and Standby Mode; Technical Specifications; Standby Mode Behavior; Setting Price of Cost;kWh

Default Icon
2 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Press UP button to set the “MINUTE“.
8. Press SET button once again and release, the time will
come back to CLOCK display mode.
9. Press UP button during the CLOCK display state, change 12-
24 hour mode.
To reset incorrect time, repeat above steps.
After you have finished, Plug the meter into a regular 240 Volts
power outlet, Plug in an appliance that you want to use and
turn the mains power on. Now the meter begins to measure
the consumption of the appliance and detect the equipment
that uses too much electricity at once.
SETTING PRICE OF COST/kWh
Press and hold FUNC. button for 5 seconds during display
state of voltage or current or power.
1. Setting price 1:
a. Press SET button once and release, SET display, the rst
digital COST/kWh flash, press UP button to set it.
b. Press SET button once again and release, the second
digital COST/kWh flash, press UP button to set it.
c. Press SET button once again and release, the third COST/
kWh flash, press UP button to set it.
d. Press SET button once again and release, the fourth
COST/kWh flash, press UP button to set it.
e. Press SET button once again and release, the radix point
COST/kWh flash, press UP button to set it.
f. Press SET button once again and release, the weekday
flash, press UP button to set it.
g. Press SET button once again and release, the hour of ON
TIME flash, press UP button to set it.
h. Press SET button once again and release, the minute of
ON TIME flash, press UP button to set it.
2. Setting price 2:
Press FUNC. button once and release after finish Setting price
1. Setting price 2, repeat above steps.
STAND BY MODE
Display of LCD will disappear without any operation after AC
power off for 10 seconds. Press any key come back to display.
SPECIFICATIONS
Power supply .......................................240V AC 50Hz
Max. load ..............................................10A, 2400W
Measure voltage range ....................200-276V AC
Measure voltage accuracy ..............+/-1%
Measure current range ....................0.01-10A
Measure current accuracy ..............+/-1% or +/-0.01 A
Measure power range ......................0.2W-2760W
Measure power accuracy ...............+/-1% or +/-0.2W
Accumulative electric
quantity range .....................................0 -9999.9kWh
Measure frequency range ...............45-65Hz
Clock accuracy ...................................+/- 1 minute per month
Power cost ........................................<0.5W
Operating temperature......................-10 oC to +40 oC
Battery ...................................................2x1.5V LR44/AG13
Battery life ............................................about 3 months
without AC power
MULTIFUNCTION POWER METER
Instructions
electrical