JY926A Coin Selector
For Detailed Product Information Please contact:
Emaar Impex Pvt. Ltd. Email: sales@emaarindia.in
302/303,Diamond Plaza, Phone: +91-22-43688 688
Lamington Road,
Grant Road.Mumbai-400004
The manual of Multi coin selector
Features:
Intelligent CPU software control, and high accuracy.
Self-programming without PC, and automatic self-test for problem
Accept different kinds of coins at the same time. Free to set up pulses' output.
Prevent not only electric shock but also electromagnetic interference.
Support multi coins with only 1 signal output.
Capable of accepting all worldwide Coins and Tokens
Specifications:
Coin diameter 15mm-32mm
Atmospheric pressure 86Kpa
106Kpa
Signal Output :Pulse
Coin thickness1.2mm-3.4mm
Accuracy rate of identification
99.5%
Speed0.6s
Working voltage DC +12V ±10%
Working humidity95%
Working current 65mA ±5%
Connecting:
The Setting Process for Parameters:
1. Hold on the button"Add" and the button "Minus" simultaneously for seconds,then letter "A" will appear from
the LED display.
2. Hold on the button "Setup" for seconds, and letter "E" will appear. Next, use the button "Add" and the button
"Minus" to choose how many kinds of coins you would like to use. Next, hold on the button "Setup" for seconds
to finish.
3. Letter "H1" will appear. Use the button "Add" and the button "Minus" to choose how many samples you would
like to insert later. Next, hold on the button "Setup" for seconds to finish.
The maximum is 30. Please choose more than 15 samples for more accurate.
4. Letter "P1" will appear. Use the button "Add" and the button "Minus" to choose the amount of output's
signals/pulses for coins. Next, hold on the button "Setup" for seconds to finish. The maximum pulse is 50.
5. Letter "F1" will appear. Use the button "Add" and the button "Minus" to choose accuracy. Next, hold on the
button "Setup" for seconds to finish.
The value is from 1 to 30, and 1 is the most accurate. Normally,5-10 will be
fine. If kinds of coins are too similar, the value should be more accurate.
6. The first kind of coin has been set up so far. Please repeat No.3- No.5 until all kinds of coins has been set up.
Letter "A" will appear again after all above procedures is finished.
7. Hold on the button " Setup" for seconds, and letter "E" will appear. Finally, turn off and turn on the power. The
setting will be stored.
You can start sampling after the setting is finished. Please choose more than 15 coins. The sampling will affect the
accuracy of coin selector.
-- RED wire
-- WHITE wire (Signal Wire)
-- Black wire
--Gray wire
Question and Answer IconNeed help?

Do you have a question about the Emaar JY926A and is the answer not in the manual?

Summary

The Setting Process for Parameters

Initialize Parameter Setting

Enter setting mode by holding 'Add' and 'Minus' buttons simultaneously to display 'A'.

Configure Coin Count

Set the number of coin types to recognize using 'Setup', 'Add', and 'Minus' buttons to display 'E'.

Set Sample Quantity

Determine the number of coin samples for accurate identification (max 30).

Configure Output Pulses

Define the number of output signals (pulses) per coin (max 50).

Adjust Accuracy Level

Select accuracy value (1-30); lower is more accurate. Recommend 5-10.

Save and Exit Setting

Hold 'Setup' to display 'E', then power cycle to store configurations.

Sampling Process

Initiate Coin Sampling

Start coin sampling by holding the 'Setup' button to display 'A1'.

Sample First Coin Type

Present the first coin type for sampling; 'A1' reappears upon completion.

Sample Subsequent Coin Types

Repeat sampling for additional coin types up to the configured number.

Finalize Sampling Process

System restarts after sampling. Product is ready for use.

AP Mode Operations

Enter AP Mode

Hold 'Setup' and 'Add' simultaneously, then 'Setup' to enter AP mode.

Configure AP Mode Value

Set AP mode value to control output pulse ratios; default is 1.

Factory Default Recovery

Initiate Factory Reset

Turn off power, hold 'Setup' and 'Add', then turn on power to reset.