GROUND SERVICING
SEPTEMBER 20, 1999
1-12-05
Page
5
Code
01
To ground the aircraft properly, proceed as follow:
Make sure that the aircraft is parked adjacent to an approved
grounding point.
NOTE: - For general grounding, use a 4-AWG extra-flexible special
PVC-insulated, low voltage cable, and a PL-055-type plug
(specification MS 3493).
- To ground the refueling nozzle or the oxygen charger
adapter, use a 3/32"-diameter steel cable (specification MIL-
W-83343, MIL-W-5424 or MIL-W-1511) with plug
(specification MIL-C-83413/4) and an alligator clip.
Examine the static ground cable for damage and to make sure that
the end-fittings are correctly attached.
CAUTION: USE THE GROUNDING POINTS SHOWN IN FIGURE
ABOVE ONLY. THE USE OF OTHER POINTS MAY
RESULT IN POOR GROUNDING.
Connect the static ground cable plug to one of the grounding points
on the lower surface of each wing leading edge and the other end
to an earth grounding point.
Connect the static grounding cable of the ground support
equipment to an earth grounding point.
Connect static grounding cable plug of ground support equipment
to one of the aircraft grounding points.
Connect the applicable ground support equipment.