AIRPLANE
OPERATIONS
MANUAL
GROUND SERVICING
SEPTEMBER 20, 1999
1-12-50
Page
3
Code
01
Servicing the toilet waste tank is accomplished as follows:
NOTE: Commercial deodorants and disinfectants can be added to the
waste tank, but the tank definitive volume must not contain
such material.
Open waste-service-panel door.
Remove the protective cap from the toilet rinse nipple.
Release the handle and open the cap of the waste drain valve.
Connect the lavatory dumping coupling of the lavatory servicing
dolly to the waste drain valve.
Connect the lavatory filling coupling to the rinse nipple.
Push the lever of the waste drain-valve actuator to open its internal
flapper valve. Do not operate the coupling handle; its operation is
not necessary.
Pull and lock the drain control handle to open the holding-tank
drain valve.
Continue the tank drainage until the waste flow stops.
Flush with water through the rinse nipple for approximately 3
minutes.
Release the control cable.
Fill the waste holding tank with 15 liters (4 gal) of water.
Pull and lock the drain control handle to open the holding-tank
drain valve.
Release the drain control handle after all liquid is drained.
Fill the waste holding tank with a maximum of 7.5 liters (2 gal) of
water and then add:
- 57 grams (2 oz.) of Monogram MC-2000 germicidal deodorant, or;
- 170 grams (6 oz.) of Mirabowl "Q" germicidal deodorant.
Disconnect the lavatory dumping and filling couplings.
Close the cap and latch the handle of the waste drain valve. The
flapper valve will close automatically when the cap is closed.
Install the cap on the toilet rinse nipple.
NOTE: The access door will close only if the waste drain valve is
correctly closed.
Close waste-service-panel door.