GROUND SERVICING
AIRPLANE
OPERATIONS
MANUAL
1-12-60
Page
18
Code
01
TEMPORARY REVISION 41.1
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
ATA
EICAS
MESSAGE
or
CONDITION
LOCATION PROCEDURE
34
AHRS 1
ATT MODE
EICAS
(1) After the airplane is brought to a
stop at the ramp or hangar, power
off the AHRS 1.
Open the circuit breaker AHRS 1.
(2) Reapply power and try to align
the AHRS in a normal fashion.
34
AHRS 2
ATT MODE
EICAS
(1) After the airplane is brought to a
stop at the ramp or hangar, power
off the AHRS 2.
Open the circuit breaker AHRS 2.
(2) Reapply power and try to align
the AHRS in a normal fashion.