AIRPLANE
OPERATIONS
MANUAL
GROUND SERVICING
TEMPORARY REVISION 41.1
1-12-60
Page
25
Code
01
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
ATA
EICAS
MESSAGE or
CONDITION
LOCATION PROCEDURE
32
BRAKE
DEGRADED
EICAS
(1) On the circuit breaker panel,
open the BRAKES OUTBD and
BRAKES INBD circuit breakers.
(2) Close the BRAKES OUTBD and
BRAKES INBD circuit breakers
on the circuit breaker panel.
(3) Press both brake pedals and
verify that the message remains
extinguished.
31
CHECK IC 2
SW
EICAS
On the circuit breaker panel, open
the IC 2 circuit breaker and close it
after a few seconds.
31
DAU 1A FAIL
(Transitory
condition of
IC)
EICAS
Check that EICAS DAU 1A and 1B,
MFD 1, EICAS DISPLAY, DISPLAY
CONTROL 1, IC 1 and IC 2 circuit
breakers are closed.
Check the SG pushbutton on the
pilot Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 1A FAIL message
appears?
YES
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.