GROUND SERVICING
AIRPLANE
OPERATIONS
MANUAL
1-12-60
Page
28
Code
01
TEMPORARY REVISION 41.1
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
ATA
EICAS
MESSAGE
or
CONDITION
LOCATION PROCEDURE
31
DAU 2
WRN
MISCOMP
(Transitory
condition of
IC)
EICAS
Check that EICAS DAU 2A and 2B,
MFD 2, EICAS DISPLAY, DISPLAY
CONTROL 2, IC 1 and IC 2 circuit
breakers are closed.
Check the SG pushbutton on the
pilot Reversionary Panel.
Is the SG pushbutton pressed when
the DAU 2 WRN MISCOMP
message appears?
YES
Open, and then, close the IC 2
circuit breaker on the overhead
circuit breakers panel.
34
DU 1 FAN
FAIL
EICAS
On the circuit breaker panel, open
and close PFD 1 circuit breaker
(D13).
34
DU 2 FAN
FAIL
EICAS
On the circuit breaker panel, open
and close MFD 1 circuit breaker
(D23).
34
DU 3 FAN
FAIL
EICAS
On the circuit breaker panel, open
and close EICAS/DISPLAY circuit
breaker (C9).
34
DU 4 FAN
FAIL
EICAS
On the circuit breaker panel, open
and close MFD 2 circuit breaker
(D12).
34
DU 5 FAN
FAIL
EICAS
On the circuit breaker panel, open
and close PFD 2 circuit breaker
(D22).
34 DU 1 OVHT EICAS
Check if the DU 1 OVHT message
appears for approximately 4 seconds
on the EICAS and then disappears.