EasyManua.ls Logo

Embraer EMB145 - Page 1618

Embraer EMB145
2662 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AIRPLANE
OPERATIONS
MANUAL
CREW
AWARENESS
REVISION 39
2-04-25
Page
5
Code
01
AOM-145/1114
CONTROLS AND INDICATORS
STALL PROTECTION SYSTEM PANEL
1 - CUTOUT BUTTON (GUARDED)
− Cuts out the associated channel.
− A striped bar illuminates inside the button to indicate that it is in
the cutout position.
2 - TEST BUTTON
− Starts the test sequence, as follows:
− Button illuminates.
− Both stick shakers actuate.
− Pusher actuates.
− Button illumination extinguishes.
NOTE: - NOTE: - Test sequence is completed within a
maximum of 5 seconds.
- The TEST button must be released at the first sign of
stick shaker actuation.
− Button is kept illuminated after an unsuccessful test or if the
system has not been tested.