FUEL
AIRPLANE
OPERATIONS
MANUAL
2-08-05
Page
8
Code
01
REVISION 39
AOM-145/1114
EICAS MESSAGES (CONT.)
TYPE MESSAGE MEANING
E1 (2) FUEL SOV CLSD
ssociated shutoff valve is
closed.
ADVISORY
APU FUEL SOV CLSD
PU fuel shutoff valve is
closed. Message remains on
for 10 seconds after APU
Master Knob is set to off. If
valve has been commanded
to close through APU Fuel
Shutoff Button or APU Fire
Extinguishing Button the
message will remain on
continuously.
FUEL XFEED OPEN
Crossfeed valve is open.
CONTROLS AND INDICATORS
FUEL SYSTEM PANEL
1 - CROSSFEED Selector Knob
LOW1
− Opens the crossfeed valve and turns off the selected
pump of the left wing tank.
OFF
− Closes the crossfeed valve.
LOW2
− Opens the crossfeed valve and turns off the selected
pump of the right wing tank.
2 - WING TANK FUEL PUMP SELECTOR KNOB
− Selects which electric pump will be operative for each wing
tank. The non-selected wing pumps remain as standby.
3 - WING TANK FUEL PUMP POWER KNOB
ON - Turns ON the selected wing fuel pump.
OFF - Turns OFF the selected wing fuel pump.