EasyManua.ls Logo

Embraer EMB145 - Page 1864

Embraer EMB145
2662 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AIRPLANE
OPERATIONS
MANUAL
AUXILIARY
POWER UNIT
REVISION 37
2-09-05
Page
11
Code
01
AOM-145/1114
EICAS INDICATIONS
1 - APU RPM INDICATION
Ranges from 0 to 120% speed.
Green from 96 to 104%.
Amber and boxed from 0 to 95% and
from 105 to 110%.
Red and boxed above 110%.
2 - APU EGT INDICATION
NORMAL OPERATION
Ranges from -54 to 927qC.
Green from -54 to 680qC.
Amber and boxed from 681 to 717qC.
Red and boxed above 717qC.
START SEQUENCE
Ranges from -54 to 927qC.
Green from -54 to 838qC.
Amber and boxed from 839 to 884qC.
Red and boxed above 884qC.
NOTE: After APU shutdown, the RPM and EGT indications are
replaced by APU OFF inscription provided the APU
Master Knob is set to OFF position and APU speed is
below 5%.
EICAS INDICATIONS