POWERPLANT
AIRPLANE
OPERATIONS
MANUAL
2-10-60
Page
4
Code
01
REVISION 40
AOM-145/1114
5 - START/STOP SELECTOR KNOB
STOP - Commands the FADEC to shut the engine down, provided
associated Thrust Lever is at IDLE.
RUN - Allows normal engine operation.
START - This is a momentary position that initiates the engine start
cycle.
NOTE: On airplanes Post-Mod. SB 145-71-0003 or S/N 145.075 and
on, each Start/Stop selector knob is equipped with a
transparent protection guard over the knob for better engine
identification.
EM145AOM102009A.DGN
OVERHEAD PANEL
1
2
3
4
5
POWERPLANT
IGNITION
FADEC
RESET ALTN
1
TAKEOFF DATA
STORE
DEC INC
SET
START/STOP
1
2
12
AUTO
OFF ON
AUTO
OFF ON
RESET ALTN
STOP
START
RUN
2
STOP START
RUN
+
POWERPLANT CONTROL PANEL