NORMAL PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-02-13
Page
4
Code
01
REVISION 37
AOM-145/1114
APU Bleed..................................................................... OPEN
Air Conditioning............................................................. AS REQUIRED
Should it be necessary to climatize the airplane:
- Both Packs ON;
- XBLEED to OPEN;
- Set both temperature controls to AUTO. If control of the Pack
2 by the cabin attendant is desired, select the corresponding
knob to ATTD. Recirculation fans and gaspers will be ON;
- Shed Buses must be set to OVRD to operate the
recirculation fans when the electrical system is energized by
the APU generator.