NORMAL PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-02-17
Page
2
Code
01
REVISION 37
AOM-145/1114
- Select HOT MIC on the control wheel communication switch;
- Actuate the test button on the mask stowage location. Check
that the blinker changes color; (*)
- The OXY ON flag must appear on the stowage box; (*)
- For EROS masks: While maintaining the RESET TEST lever
(TEST/SHUTOFF sliding control) depressed, check that the
blinker changes color momentarily, and then depress the
PRESS-TO-TEST regulator for 1 second; or
For Puritan Bennett or B/E Aerospace masks: Set the
regulator’s control knob to EMERGENCY and momentarily
actuate the test button on the mask stowage location;
- Check that the blinker changes color;
- The OXY ON flag must appear on the box; (*)
- The sound of oxygen flowing must be heard momentarily on
the speaker, thereby assuring the microphone electrical
integrity;
- Set the mask to 100%; (*)
- After finishing the test, select the BOOM position on the
Audio Panel.
(*) Applicable only to Puritan Bennett or B/E Aerospace masks.
If there is an observer on the jump seat, check the observer oxygen
mask as follows:
- Select the MASK position on the observer Audio Panel;
- Set the mask to 100%;
- Select SPKR on the Audio Panel and set the volume to mid-
range;
- Select HOT MIC on the control wheel communication switch;
- For EROS masks: Depress the PRESS-TO-TEST regulator
for 1 second; or
For Puritan Bennett or B/E Aerospace masks: Turn the
regulator knob to the EMERGENCY position momentarily
and then turn back the knob to 100% position;
- The sound of oxygen flowing must be heard momentarily on
the speaker, thereby assuring the microphone electrical
integrity;
- After finishing the test, select the BOOM position on the
Audio Panel.