AIRPLANE
OPERATIONS
MANUAL
NORMAL PROCEDURES
REVISION 37
1-02-29
Page
1
Code
01
AOM-145/1114
AFTER START
Ground Equipment........................................................ REMOVED
Do not start taxiing before receiving confirmation from the ground
crew that the airplane is free to taxi. Then acknowledge that and
switch OFF the cockpit dome lights.
It is recommended that the taxi light be ON during taxi even during
daytime.
NOTE: The steering handle engagement actuation with the Nose
wheels beyond their operational limits may cause damage to
the Nose Wheel Steering System.
Electrical System .......................................................... SET
If the SHED BUSES are set to OVRD, switch them to AUTO.
APU............................................................................... AS REQUIRED
Set the APU ON or OFF according to the electrical and
pressurization systems. The APU usage shall be defined for a
specific operation in order to minimize the overall costs.
FADEC.......................................................................... RESET/ALTN
This swapping of the FADECs is important because it ensures that
both the controlling and the standby FADECs are properly set.
Electric Hydraulic Pumps.............................................. AUTO
Set the electric hydraulic pumps to AUTO after start.
Windshield Heating....................................................... AS REQUIRED
Turn Windshield Heating ON if icing conditions or windshield
fogging is encountered or anticipated.
For airplanes equipped with PPG windshield, the windshield
heating system may be selected ON during all flight phases.