LOSS OF ALL GENERATORS
EICAS CAUTION: GEN 1, 2, 3, 4 OFF BUS and APU GEN OFF BUS
LIGHT: Master Caution
Airspeed ........................................................................ MAXIMUM
250 KIAS
Altitude .......................................................................... MEA OR
10000 ft,
WHICHEVER
IS HIGHER
Essential Power ............................................................ ON
Crew Oxygen ................................................................ AS REQUIRED
Passenger Oxygen ....................................................... AS REQUIRED
Emergency Lights ......................................................... OFF
If required, turn on Emergency Lights before landing.
Land at the nearest suitable airport.
Landing Gear ........................................................... DOWN
FLAPS POSITION MINIMUM AIRSPEED
0° TO 8° V
REF 45
+ 30 KIAS
9° TO 21° V
REF 45
+ 10 KIAS
22° TO 44° V
REF 45
+ 5 KIAS
45° V
REF 45
CAUTION:
• MULTIPLY THE UNFACTORED LANDING DISTANCE
FOR FLAPS 45° BY 1.95.
• BATTERY DURATION IS 40 MINUTES. THIS
DURATION IS VALID WITH UP TO THREE APU START
ATTEMPTS IN FLIGHT.