AIRPLANE
OPERATIONS
MANUAL
EMERGENCY
PROCEDURES
REVISION 40
1-03-11
Page
5
Code
03
AOM-145/1114
ENGINE REVERSER FAILURE/DISAGREE
EICAS CAUTION: ENG1 (2) REV FAIL or
ENG1 (2) REV DISAGREE
LIGHT: Master Caution
Do not takeoff.
During landing:
Affected Thrust Lever .............................................. IDLE
In flight:
N1 ............................................................................ CHECK
If N1 is decreasing:
Associated Thrust Lever..................................... IDLE
Airspeed ............................................................. MAXIMUM
200 KIAS
PRECAUTIONARY ENGINE
SHUTDOWN Procedure................................ ACCOMPLISH
Land at the nearest suitable airport.
REJECTED TAKEOFF (AT OR BELOW V
1
)
CONDITION: In the event of engine failure, engine fire, or any
condition affecting safety of flight, occuring prior to V1.
Thrust Levers................................................................ IDLE OR MAX
REVERSE
Brakes........................................................................... APPLY
MAXIMUM
Directional Control ........................................................ MAINTAIN
Immediately after stopping:
Precautionary Engine Shutdown or
ENGINE FIRE, SEVERE DAMAGE OR
SEPARATION Procedure........................................ AS REQUIRED