AIRPLANE
OPERATIONS
MANUAL
EMERGENCY
PROCEDURES
REVISION 40
1-03-24
Page
1
Code
03
AOM-145/1114
BLEED LEAK
EICAS WARNING: BLD 1 (2) LEAK or BLD APU LEAK
LIGHT: Master Warning and leak inscription in the associated bleed
button illuminated.
Crossbleed.................................................................... CLOSE
Confirm the failed side and proceed.
Associated Bleed and APU Bleed................................. CLOSE
Check on EICAS the following messages: CROSS BLD SW OFF
and associated BLD VLV CLSD. Check APU bleed button not
illuminated.
Altitude .......................................................................... MAX 25000 ft
MINIMUM MEA
Icing Conditions ............................................................ EXIT/AVOID
Wait 3 minutes.
If the message remains on, but the associated advisory message on
EICAS (BLD 1 or 2 VLV CLSD) indicates the valve is closed:
Opposite Bleed ........................................................ CLOSE
Associated Bleed ..................................................... OPEN
Wait 3 minutes.
If the message still remains:
Associated Bleed................................................ CLOSE
Altitude................................................................ MEA OR
10000 ft
WHICHEVER
IS HIGHER
If the message remains on and is associated with a failed engine bleed
valve (BLD 1 or 2 VLV FAIL caution message):
Associated Thrust Lever.......................................... IDLE
Wait 3 minutes.
If the message still remains:
Associated Engine (or APU)............................... SHUTDOWN