EMERGENCY
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-30
Page
4
Code
03
REVISION 40
AOM-145/1114
CONTINUED FROM PREVIOUS PAGE
Upon water contact:
Start/Stop Selectors................................................. STOP
EMERGENCY EVACUATION Procedure ............... ACCOMPLISH
WARNING:
AIRPLANE EVACUATION MUST BE DONE THROUGH
THE OVERWING EMERGENCY EXITS ONLY. DO NOT
OPEN REMAINING DOORS.
EMERGENCY EVACUATION
Parking Brake (if necessary)......................................... APPLY
Cabin............................................................................. DEPRESSURIZE
Fire Extinguishing Handles ........................................... PULL
APU Fuel Shutoff Valve ................................................ CLOSE
APU and Engine Fire Extinguishing
Bottles (if necessary) ............................................... DISCHARGE
Ventral Tank Transfer Knob (if applicable) ................... OFF
Electric Fuel Pumps ...................................................... OFF
Electric Hydraulic Pumps .............................................. OFF
Cabin Crew ................................................................... NOTIFY
Emergency Lights ......................................................... ON
Evacuation .................................................................... INITIATE
NOTE: Cockpit door blow-out panels may be broken to be used as an
alternative way to leave cockpit.
ATC ............................................................................... NOTIFY
Before leaving the airplane:
Batteries................................................................... OFF