ABNORMAL
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-35
Page
2
Code
03
REVISION 17
MAIN DOOR BLOCKED
LIGHT: Door Blocked Closed (Attendant’s panel)
To open the door on ground:
Check that the door opening area is free of both people and ground
equipment.
Hydraulic System 1 ..................................................OFF
Main Door Alternative Opening Valve ......................ACTUATE
DURING
2 MINUTES
Unlock the door and open it.