EasyManua.ls Logo

Embraer EMB145 - Page 470

Embraer EMB145
2662 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ABNORMAL
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-40
Page
2
Code
03 REVISION 40
AOM-145/1114
FUEL CROSSFEED FAILURE
EICAS CAUTION: FUEL XFEED FAIL
LIGHT: Master Caution
Fuel Imbalance.............................................................. MONITOR
Asymmetric Thrust ........................................................ AS REQUIRED
FUEL IMBALANCE
EICAS CAUTION: FUEL IMBALANCE
LIGHT: Master Caution
If fuel imbalance is confirmed:
CROSSFEED OPERATION
Procedure ........................................................... ACCOMPLISH
REFUELING COMPARTMENT DOOR OPEN
EICAS CAUTION: FUELING DOOR OPN
LIGHT: Master Caution
On ground:
Check the door for positive locking before takeoff. If the message
remains, repair is required before takeoff.
ENGINE FUEL SHUTOFF VALVE FAILURE
EICAS CAUTION: E1 (2) FUEL SOV INOP
LIGHT: Master Caution
Confirm the failed valve.
Engine Fuel Indications................................................. MONITOR
If the message has been presented during a fire procedure:
Crossfeed................................................................. OFF
Associated Fuel Pumps ........................................... OFF
If valve is confirmed closed during normal operation (fuel flow
decreasing to zero):
Fire Extinguishing Handle ........................................ CHECK IN
If valve remains closed and it is not possible to restart the affected
engine, land at the nearest suitable airport.
PRECAUTIONARY ENGINE
SHUTDOWN Procedure..................................... ACCOMPLISH
If engine is running normally, disregard the message.

Other manuals for Embraer EMB145