AIRPLANE
OPERATIONS
MANUAL
ABNORMAL
PROCEDURES
REVISION 38
1-03-45
Page
3
Code
03
AOM-145/1114
ABNORMAL ENGINE START
Abort engine start immediately when:
Only on ground, no light-up in 10 seconds after the first fuel flow
indication.
NOTE: The start should not be aborted if fuel flow drops to
zero pph immediately after light-up.
ITT approaches start limit.
N2 remains steady or decreases for more than 30 seconds after
light off.
N2 indicates no rotation up to 10 seconds after the start
command.
Any unusual noise or vibration occurs.
Engine instruments indicate abnormal conditions.
Visible burning on the exhaust pipe.
Oil pressure does not reach at least 34 psi after the engine
reaches stabilized idle.
To abort start:
Associated Thrust Lever.......................................... IDLE
Start/Stop Selector .................................................. STOP
If fire occurs or engine does not shutdown:
Fire Extinguishing Handle........................................ PULL
ENGINE DRY MOTORING Procedure......................... ACCOMPLISH