ABNORMAL
PROCEDURES
AIRPLANE
OPERATIONS
MANUAL
1-03-45
Page
8
Code
03
REVISION 38
AOM-145/1114
CONTINUED FROM PREVIOUS PAGE
Start/Stop Selector.............................................. START, THEN
RUN
Engine Indication ................................................ MONITOR
Check ignition. Check N2 rising. Observe limits. Abort start
immediately if an Abnormal Engine Start is detected.
If Windshield Heating and Electric Hydraulic Pump were turned
off before engine start:
Windshield Heating........................................ ON
Electric Hydraulic Pump ................................ AUTO
Windmilling start:
Airspeed................................................................... ABOVE
260 KIAS
Minimum N2............................................................. 10%
Start/Stop Selector................................................... START, THEN
RUN
ITT and N2 ............................................................... MONITOR
Observe limits. Abort start immediately if an Abnormal Engine Start
is detected.
NOTE: - Windmilling start will be slower than an assisted start.
- Windmilling start with N2 above 30% and increasing, the
loss of altitude may be minimized, by reducing airspeed.
- Initiate windmilling start with N2 as high as possible.
Windmilling starts are not possible with N2 below 10%.
Once N2 is below 10%, it may not be recovered.
After start:
Affected Engine Bleed ............................................. AS REQUIRED
Crossbleed............................................................... AUTO
APU Bleed ............................................................... AS REQUIRED
CONTINUES ON NEXT PAGE