AIRPLANE
OPERATIONS
MANUAL
ABNORMAL
PROCEDURES
REVISION 41
1-03-56
Page
5
Code
03
Copyright © by Embraer. Refer to cover page for details.
AOM-145/1114
PACK OVERLOAD
EICAS Caution: PACK 1 (2) OVLD
LIGHT: Master Caution
Associated Temperature & Mode Selector................... AUTO/
12 O’CLOCK
Associated Pack ........................................................... OFF
Wait 3 minutes.
Associated Pack ........................................................... ON
NOTE: In case the message still displayed after reset, report to the
maintenance personnel.
If the message remains on:
Associated Temperature & Mode Selector.............. MANUAL/
12 O´CLOCK
Associated Pack ...................................................... OFF
Wait 3 minutes.
Associated Pack ...................................................... ON
If the message still remains on:
Associated Pack ...................................................... OFF
Altitude..................................................................... MAX 25000 ft
MINIMUM MEA
Associated Engine Bleed......................................... OPEN
If both packs have been shutoff:
Altitude..................................................................... MEA OR
10000 ft,
WHICHEVER
IS HIGHER
Pressurization Mode Selector.................................. MAN
Pressurization Manual Controller ............................ AS REQUIRED
If required:
Pressurization Manual Controller ....................... FULL UP
NOTE: At least one bleed source, engines or APU, must be kept
open.